background image

What's inside the box? 

 

An energizer 

 

A user manual 

If you have purchased a 36 J RS energizer or a 36 J RSE 
energizer, you will also find: 

 

A Remote Control Handset 

 

A leather pouch with a clip for the Remote Control 
Handset 

How does an electric fence work? 

An electric fence system comprises an energizer and an 

insulated fence. The energizer puts very short pulses of 
electricity onto the fence line. These pulses have a high 
voltage, but are of very short duration (less than 3/10,000ths 

of a second). However, a shock from an electric fence pulse is 
very uncomfortable and animals quickly learn to respect 
electric fences.  An electric fence is not only a physical 

barrier, but is also a strong psychological barrier. 

What are the benefits of an electric fence? 

An electric fence has many benefits over conventional 

fencing: 

 

Requires less labour and materials to construct. 

 

Flexibility to change or add paddocks when required.  

The use of strip grazing techniques can allow temporary 
fencing to be quickly and easily erected or removed. 

 

Controls a broader range of animals. 

 

Minimises damage to expensive livestock when 
compared with other fencing mechanisms, for example 

barbed wire. 

 

Parts of the energizer 

 

Key to symbols on the energizer 

 

Fence earth terminal. Connect the fence earth 
terminal to the earth system. 

 

Fence output terminal. Connect the fence output 
terminal to the fence. 

 

The energizer should be opened or repaired only by 
qualified personnel in order to reduce the risk of 
electric shock. 

  Read full instructions before use. 

 

Product Information: Please recycle this product in 
accordance with the regulations for your country. 

 

Indicates that the energizer is of a double-insulated 
construction. 

 

Installation 

 

Mount the energizer close to a power outlet. 

 

Mount the energizer out of reach of children. 

 

Use the template printed on the back page of this 

manual to mount the energizer onto a wall or beam. 

 

Connect the Fence earth terminal to a separate earth 
system that is at least 10 m (33') from other earth 
systems. See 

Installing and testing an earth system

 on 

page 7. 

 

Connect the Fence output terminal to the fence. Use 

either the low voltage (yellow) or high voltage (red) 
fence output terminal. 

 

Energizer fence output terminals 

The energizer has two Fence output terminals – high voltage 
(red) and low voltage (yellow).  Although the low voltage 

terminal produces a lower voltage than the high voltage 
terminal, it 

delivers the same amount of energy

The low voltage terminal is used in dry areas, where sparks 
from a higher voltage may cause a fire, or when special fire 
department regulations are in force.  This terminal can also 

be used to configure a bi-polar fencing system. 

 

Operation 

 

Turn on the power supply. 

 

Reading voltage 

The LED display shows the voltage at the output terminals of 
the energizer. 
When first connected to the power source, all light segments 
on the LED display illuminate.  They then illuminate 
separately from left to right and back again.  This indicates 

that the energizer is operating normally.  The LED display, 
then, briefly displays a light sequence that identifies the 
address setting of the energizer.   
After three seconds, the energizer starts pulsing. Each of the 
light segments on the LED display represent an increment of 

approximately 1 kV (1000 V) of output voltage.  For example, 
if the first 4 segments are illuminated at each pulse, the 
output voltage is approximately 4 kV (4000 V).   

Summary of Contents for 15 J R

Page 1: ...c fencing and your Tru Test energizer Congratulations on your purchase of a Tru Test energizer This product has been constructed using the latest technology and construction techniques It has been eng...

Page 2: ...regulations for your country Indicates that the energizer is of a double insulated construction Installation Mount the energizer close to a power outlet Mount the energizer out of reach of children U...

Page 3: ...the fence until the beeping has stopped The energizer is designed to automatically reactivate following an interruption to the input power supply This will occur even if it was deactivated using the...

Page 4: ...OFF appears on the screen 4 Press to move to the next setting 5 Press to switch off the Remote Control Handset Backlight The remote control has a backlight for better screen visibility when there is...

Page 5: ...zer The large red light on the left illuminates for 6 seconds as the energizer receives the command The energizer then resumes in Standby mode with only the large green light on the right flashing 6 P...

Page 6: ...res conductive soils These fences are often referred to as all live or earth return fences Alternative installation For poor conductivity soils dry or sandy a fence return or earth wire return system...

Page 7: ...clip the other lead to the last earth rod The voltmeter should not read more than 0 3 kV Anything higher than this indicates that better earthing is required Either add more earth rods or find a bette...

Page 8: ...s shall be avoided wherever possible If such a crossing cannot be avoided it shall be made underneath the power line and as nearly as possible at right angles to it If connecting leads and electric an...

Page 9: ...itions is not guaranteed Check for spark gaps and loose wire joints in the fence Severe or multiple spark gaps reduce the effectiveness of the remote control Use the fault finding function to locate f...

Page 10: ...y replace A double insulated energizer is marked with the words DOUBLE INSULATION or DOUBLE INSULATED and or the symbol below Product specifications 15 J R 20 J R 36 J R and 36 J RS Power Consumption...

Page 11: ...11...

Page 12: ...12 200 mm 7 7 8 200 mm 7 7 8 200 mm 7 7 8 Actual size Diagram shown 40 of actual size...

Reviews: