10
Servicing
This energizer contains no user serviceable parts. It must be returned to a Tru-Test-appointed service agent for repair. If the supply
cord is damaged it must only be replaced by a Tru-Test-appointed service agent, as a special cord is required.
This energizer uses Double Insulation, where two systems of insulation are provided instead of grounding. No equipment grounding
means is provided in the supply cord of a double-insulated energizer, nor should a means for equipment grounding be added to
the energizer. Servicing a double-insulated energizer requires extreme care and knowledge of the system and should only be done
by qualified service personnel. Replacement parts for a double-insulated energizer must be identical to the parts they replace. A
double-insulated energizer is marked with the words DOUBLE INSULATION or DOUBLE INSULATED and/or the symbol below.
Product specifications
15 J R
20 J R
36 J R and 36 J RS
Power Consumption
20 W
33 W
52 W
Maximum Output Voltage
up to 8900 V open circuit
up to 9500 V open circuit
up to 9400 V open circuit
up to 7900 V at 500
Ω
up to 8900 V at 500
Ω
up to 8400 V at 500
Ω
Maximum Output Energy
up to 14.6 J at 75
Ω
up to 22.0 J at 50
Ω
up to 36.5 J at 50
Ω
up to 5.8 J at 500
Ω
up to 7.3 J at 500
Ω
up to 6.7 J at 500
Ω
Stored Energy
20 J
34 J
54 J
Europe only
15 J RE
20 J RE
36 J RE and 36 J RSE
Power Consumption
20 W
33 W
52 W
Maximum Output Voltage
up to 7300 V open circuit
up to 7300 V open circuit
up to 7600 V open circuit
up to 6400 V at 500
Ω
up to 6400 V at 500
Ω
up to 6600 V at 500
Ω
Maximum Output Energy
up to 14.6 J at 75
Ω
up to 22.0 J at 50
Ω
up to 36.5 J at 50
Ω
up to 4.5 J at 500
Ω
up to 4.8 J at 500
Ω
up to 4.9 J at 500
Ω
Stored Energy
20 J
34 J
54 J