TractionAir
6
Fuse
The TractionAir control mechanism only draws
0.75 Amp (single channel). Where possible
power the unit from a spare 2 Amp fuse in the
truck’s fuse board. If this is not practical use
the 2 or 3 Amp inline fuse supplied with the kit.
Pressure Cell Installation
1.
Mount the pressure cell in a position within the chassis to avoid damage.
a.
Do not mount the enclosure close to any heat source. e.g. exhaust
b.
Provided in each kitset are four ½” rubber washers approx.
15mm long. These are to reduce vibration. Fit them between the
truck frame (mounting plate) and the Alloy Enclosure bracket.
Tighten the ½” retaining bolts and lock nuts until the rubber
washers are compressed to around half their starting length.
1. Bolt
3. Rubber Isolator
2. Washer
4. Washer & Nut