UBS-VI-V08E
6.2Installation condition
●
Install and use the driver in the environment described as the following:
※
Indoor (without direct sun light exposure) or the place that is well ventilated and easy for
heat
radiation. Don
’t not expose to the sunlight directly.
※
Ambient temperature:
Controller0
℃
~
+40
℃
(Avoid freezing).
Motor 0
℃~
+50
℃
(Avoid freezing)
※
Ambient humidity: Below 85% (Avoid condensation).
※
The place that will not be affected by water, oil, corrosive and flammable gas or dust.
※
The place that will not affected by continuous vibration.
●
When the driver is installed in an enclosed place or a place where a heating source exists
nearby, please watch out for the temperature rise of the driver. It is recommended to use
a fan for forced cooling and maintaining the temperature of the driver at below 40
0
C so
as to avoid excessive temperature inside the driver and activation of the overheat
protection function.
●
Keep conductive objects (cutting powders, bolts and electrical wire chips, etc.) from
getting into the driver.
●
Installing multiple drivers:
When you install and anchor multiple drives together, be sure to keep a spacing over 20mm
between each drive and the drive should have a spacing over 25mm from other peripherals.
以上