background image

 

Tr

 

  UBS Series Brushless DC Motor Driver User

’s Manual 

 

 

 

11

 

                             

UBS-VI-V08E

 

 

 

 

6.2Installation condition 

 

Install and use the driver in the environment described as the following: 

Indoor (without direct sun light exposure) or the place that is well ventilated and easy for 

heat 

radiation. Don

’t not expose to the sunlight directly. 

Ambient temperature:   

Controller0

+40

 (Avoid freezing). 

Motor        0

℃~

+50

 (Avoid freezing) 

Ambient humidity: Below 85% (Avoid condensation). 

The place that will not be affected by water, oil, corrosive and flammable gas or dust. 

The place that will not affected by continuous vibration.

 

When the driver is installed in an enclosed place or a place where a heating source exists 

nearby, please watch out for the temperature rise of the driver. It is recommended to use 
a fan for forced cooling and maintaining the temperature of the driver at below 40

0

C so 

as  to  avoid  excessive  temperature  inside  the  driver  and  activation  of  the  overheat 
protection function.

 

Keep  conductive  objects  (cutting  powders,  bolts  and  electrical  wire  chips,  etc.)  from 
getting into the driver.

 

Installing multiple drivers: 

When you install and anchor multiple drives together, be sure to keep a spacing over 20mm 
between each drive and the drive should have a spacing over 25mm from other peripherals. 

 

 

以上

 

Summary of Contents for Brushless DC Motor Driver

Page 1: ...ushless DC Motor Driver User s Manual 1 UBS VI V08E U UB BS S S Se er ri ie es s U UB BS S S Se er ri ie es s B Br ru us sh hl le es ss s D DC C M Mo ot to or r D Dr ri iv ve er r U Us se er r s s M M...

Page 2: ...Disassembly voids all warranties Precautions for maintenance Check the ambient environments clean the system equipment to remove dust and tighten the screws periodically Also pay attention to the foll...

Page 3: ...2 1Specs 3 2 2Specs of motor driver 3 3 Verifying the combination 4 3 1Verifying the content of package 4 3 2Verifying the product name and spec 4 4 Function of driver 5 5 Installation 7 5 1Wiring 7...

Page 4: ...eed Indicator Accessories Extension Cable Power 110V or 220V Depending on driver model Motor Noise Filter NSF No Fuse Breaker NFB Protect the power and circuit Magnetic Contactor MC When abnormal cond...

Page 5: ...OUT ALARM OUT Functions Controlling the motor run and stop via RUN STOP Speed range 250 2000RPM motor outputs by FLAT TORQUE It has the instantaneous brake stop CW CCW natural stop slow start slow dow...

Page 6: ...Name of motor Name of driver 20W AC110V 115V 6B020S 1N UBD020 1 AC220V 230V 6B020S 2N UBD020 2 40W AC110V 115V 6B040S 1N UBD040 1 AC220V 230V 6B040S 2N UBD040 2 60W AC110 115V 9B060S 1N UBD060 1 AC22...

Page 7: ...R S O A O 4 5 6 2 3 1 AC RUN STOP UNIT DC BRUSHLESS MOTOR DRIVER 0 10 20 30 40 50 60 70 80 90 100 ALARM POWER Scale of speed setting ALARM LED Red Front panel RUN STOP switch POWER LED Green External...

Page 8: ...of driver AC contact Please connect power line N and L FG contact Please contact to frame ground of the system NC contact Not used Note The mark of driver voltage specs 1 indicates Single phase AC110...

Page 9: ...OFF ON OFF SW1 F G F G AC AC R O O T M 6 A O COM 7 CW CCW STOP RUN S O A R AC L N Gearhead Motor Be sure the motor connector is fully inserted to the driver connector Motor cable AC power input A B L...

Page 10: ...rotation CW CCW please push the switch RUN STOP to the STOP side Motor can not be reversed instantaneously it will cause the motor fault and wait the motor comes to a complete stop before switching P...

Page 11: ...r to driver Motor lead length 45cm Extension cable length Model of extension cable Length m CB 010 1 CB 020 2 CB 030 3 CB 050 5 CB 100 10 Actual cable length Required length 10cm Connecting the AC Pow...

Page 12: ...3 90 81 53 26 5 50mm 50mm M3 4 M3 4 25mm Driver case Leave sufficient space for air to pass between the case Mounting plate M4 Screws X2 Leave sufficient space for air to pass between the driver Note...

Page 13: ...e that will not affected by continuous vibration When the driver is installed in an enclosed place or a place where a heating source exists nearby please watch out for the temperature rise of the driv...

Page 14: ...n Model UBD020 UBD040 UBD060 UBD090 Common size 0 10 20 30 40 50 60 70 80 90 100 RUN STOP UNIT DC BRUSHLESS MOTOR DRIVER ALARM POWER F G F G AC AC R O O T M 6 A O COM 7 CW CCW STOP RUN S O A R BRAKE 3...

Page 15: ...protection All packaging material is recyclable and reusable If disposing of used product please recycle by type as per waste disposal procedures Protect the green earth with your care and commitment...