dehumidifier TTK 70 HEPA

Storage

Before

 storing the device, proceed as follows:

• Drain the remaining condensate from the device and the

condensation drain hose (see chapter Maintenance).

• Hold onto the mains plug while pulling the power cable out

of the mains socket.

When the device is not being used, observe the following
storage conditions:

• Only store the device in a room measuring more than 4 m

2

.

• dry and protected from frost and heat
• in an upright position where it is protected from dust and

direct sunlight

• with a cover to protect it from invasive dust, if necessary
• Place no further devices or objects on top of the device to

prevent it from being damaged.

Assembly and start-up

Scope of delivery

• 1 x device
• 1 x hose for the condensate drain, 30 cm length, 

10 mm diameter

• 1 x air filter
• 1 x HEPA filter
• 1 x manual

Unpacking the device

1. Open the cardboard box and take the device out.
2. Completely remove the packaging.
3. Fully unwind the power cable. Make sure that the power

cable is not damaged and that you do not damage it during
unwinding.

Start-up

When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical annex.

A

B

C

C

D

• Before restarting the device, check the condition of the

power cable. If there are doubts as to the sound condition,
contact the customer service.

• Only position the device in rooms where potentially leaking

refrigerant cannot accumulate.

• Only position the device in rooms where there is no source

of ignition (e.g. open flames, an active gas appliance or an
electric heater).

• Only put up the device in an upright, stable position on firm

ground.

• Do not create tripping hazards when laying the power

cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.

• Make sure that extension cables are completely unrolled.
• When positioning the device, keep a sufficient distance to

heat sources.

• Make sure that no curtains or other objects interfere with

the air flow.

• When positioning the device, particularly in wet areas,

secure it locally with an RCD (residual current device)
which complies with the respective regulations.

Summary of Contents for TTK 70 HEPA

Page 1: ...TRT BA TTK70HEPA TC211001TTRT09 001 EN TTK 70 HEPA EN OPERATING MANUAL DEHUMIDIFIER...

Page 2: ...y before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the war...

Page 3: ...device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is no source of ignition e g open flames an active gas appliance or an electric he...

Page 4: ...which require the housing to be opened must only be carried out by specialist companies for cooling and air conditioning or by Trotec Safety signs and labels on the device Note Do not remove any safe...

Page 5: ...through the air inlet the air filter the HEPA filter the evaporator and to the condenser located behind it The air is cooled at the cold evaporator until it is below the dew point Water vapour contain...

Page 6: ...s to be transported together can be gathered from the applicable transport regulations To make the device easier to transport it is fitted with a carry handle Before transporting the device observe th...

Page 7: ...r cable is not damaged and that you do not damage it during unwinding Start up When positioning the device observe the minimum distance from walls or other objects as described in the chapter Technica...

Page 8: ...ion mode even after the set nominal value has been reached until the device is switched off 25 18 12 15 13 14 26 19 30 28 11 27 16 17 20 21 22 23 29 24 Operating elements No Designation Meaning 11 LED...

Page 9: ...e flashes 2 Repeatedly press the MODE button 12 until the operating mode LED Dehumidification 30 flashes The LED of the selected operating mode flashes for approx 5 seconds before the operating mode i...

Page 10: ...n set it will not be saved The device memorises the settings even during short power failures In this case the device automatically switches back on The previous settings are saved except for the time...

Page 11: ...dry In addition the device may also be used as a kind of clothes dryer to dry wet laundry in living or working spaces When positioning the device or a clothes horse please observe the minimum distance...

Page 12: ...nsure that the relative room humidity complies with the technical data Check the preselected desired room humidity level The relative humidity in the room must be above the selected range If necessary...

Page 13: ...nd or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign objects and...

Page 14: ...entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning or by Trotec Safety signs a...

Page 15: ...Errors and faults Make sure that the HEPA filter is installed before switching the device on The operating life is approx 1 year depending on the degree of air pollution If required visually inspect...

Page 16: ...er located in the air inlet cover The filter has to be cleaned as soon as it is dirty It becomes clear that it is contaminated if the device s performance is reduced see chapter Errors and faults 1 Re...

Page 17: ...k over a suitable drain e g a toilet a wash basin or a sink 3 Rinse the tank with clear water Clean the tank regularly using a mild cleaning agent no detergent 4 Refit the condensation tank into the d...

Page 18: ...r Technical annex Technical data Parameter Value Model TTK 70 HEPA Max dehumidification performance 24 l 24 h Dehumidification performance 30 C and 80 RH 20 l 24 h Air flow rate 140 m3 h Operating ran...

Page 19: ...EN 19 dehumidifier TTK 70 HEPA Circuit diagram...

Page 20: ...3 Electrical Box 26 Handle 2 Guided Light 14 Fixed Mount R 27 Tank Cover 3 Front Shell 15 Main PCB 28 Foam 4 Handle R 16 Electrical Cover 29 Water Tank 5 Wind Wheel 17 Handle L 30 Water Level Mark 6 C...

Page 21: ...or many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment authorised for your country The separate...

Page 22: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: