11
dehumidifier TTK 70 HEPA
2. Push one end of the hose onto the connection for the
condensation drain hose (
6
).
3. Refit the condensation tank into the device. When doing
so, make sure that the condensation drain hose does not
slip out of place or does not become disconnected from
the connection.
4. The other hose end must be guided to a sufficiently
dimensioned collection container or to a suitable drain
(e.g. floor drain). Please note that the hose must not be
kinked nor guided upwards.
5. Remove the hose if you want to collect the condensate in
the condensation tank again. Allow the hose to dry prior to
storage.
Automatic defrost
At low ambient temperatures, ice may form at the evaporator
during dehumidification. The device will then carry out an
automatic defrost. Dehumidification is briefly interrupted during
defrosting. The fan keeps running. The duration of the defrost
process can vary. Do not switch off the device during automatic
defrost. Do not remove the mains plug from the mains socket.
The (
27
) LED is illuminated during automatic defrost.
Drying laundry
In addition, the device may also be used as a kind of clothes
dryer to dry wet laundry in living or working spaces.
When positioning the device or a clothes horse, please observe
the minimum distances specified in the technical data.
The following humidity values are suitable for drying laundry:
• cupboard dry = 46 % relative humidity
• iron dry = 58 % relative humidity
• slightly dried = 65 % relative humidity
Adjust the settings for the relative humidity level to the device
(e.g. 60 % relative humidity for iron dry laundry). If necessary,
use a measuring device to determine the humidity level.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
• Press the
On/off
button (
18
) to activate the stand-by mode.
The LED (
19
) flashes.
• Hold onto the mains plug while pulling the power cable out
of the mains socket.
• Empty the condensation tank, if need be.
• Clean the device according to the Maintenance chapter.
• Store the device according to the Transport and storage
chapter.
Available accessories
Warning
Only use accessories and additional equipment
specified in the operating manual.
Using insertion tools or accessories other than those
specified in the operating manual may cause a risk of
injury.
Designation
Article number
HEPA filter