EN
15
dehumidifier TTK 70 HEPA
Cleaning and replacing the HEPA filter
Note
Do not operate the device without a HEPA filter
inserted!
Note
The HEPA filter cannot be washed and must be
replaced if necessary.
Note
The lifetime of the HEPA filter depends on the ambient
conditions and the application period of the device.
• The HEPA filter must be cleaned or replaced if it is very
dirty. This is brought to light e.g. by a reduced capacity
(see chapter Errors and faults).
• Make sure that the HEPA filter is installed before switching
the device on.
The operating life is approx. 1 year, depending on the degree of
air pollution.
If required, visually inspect the HEPA filter for dirt.
1. Remove the cover of the air inlet.
2. Pull the strip to take the HEPA filter out of the device.
3. Clean the HEPA filter with a dry, lint-free cloth if it is
slightly dirty. If heavily soiled, dispose of the HEPA filter in
accordance with the national regulations and remove the
new HEPA filter from the plastic cover.
4. Insert the cleaned / new HEPA filter into the device. Make
sure that the strip is positioned as indicated.