4
EN
dehumidifier TTK 175 S / TTK 355 S
•
Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
•
Please note that the refrigerant is odourless.
•
Only install the device in compliance with the national
installation regulations.
•
Please observe the local regulations.
•
Observe the national gas regulations.
•
Only install, operate and store the device in a room
measuring more than 13 m
2
.
•
Only install, operate and store the device in a room
measuring more than 4 m
2
.
•
Store the device in a way that no mechanical damage can
occur.
•
Please note that the connected pipelines must not contain
any sources of ignition.
•
R290 is a refrigerant that complies with European
environmental regulations. No part of the cooling circuit
may be perforated.
•
R454C comes with a low GWP factor (Global Warning
Potential) of 146 and an ODP (ozone depletion potential)
of 0.
•
Observe the maximum refrigerant capacity in the technical
data.
•
Do not drill through or burn.
•
Do not use any means other than those recommended by
the manufacturer for accelerating the defrosting process.
•
Every person working with or at the refrigerant circuit must
be able to provide a certificate of qualification issued by a
body accredited by the industry, demonstrating their
competence in the safe use of refrigerants based on a
procedure well-known in the industry.
•
Service work may only be carried out in accordance with
the manufacturer's specifications. If maintenance and
repair work require the support of additional persons, the
person trained in handling flammable refrigerants shall
continuously supervise the work carried out.
•
The entire refrigerant circuit is a maintenance-free,
hermetically sealed system and may only be maintained or
repaired by specialist companies for cooling and air-
conditioning or by Trotec.
Intended use
Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
Intended use comprises:
•
dehumidifying and drying:
– living rooms, bedrooms and basements
– holiday homes, camper vans
•
maintaining the dryness of:
– storage spaces, archives, laboratories, garages
– changing rooms etc.
Foreseeable misuse
•
Do not place the device on wet or flooded ground.
•
Do not place any objects, e.g. clothing, on the device.
•
Do not use the device out of doors.
•
This device must not be used in wet rooms (e.g. laundry
rooms).
•
Never immerse the device in water.
•
Do not make any unauthorised modifications, alterations or
structural changes to the device.
•
Any use other than the intended use is regarded as a
reasonably foreseeable misuse.
Personnel qualifications
People who use this device must:
•
be aware of the dangers that occur when working with
electric devices in damp areas.
•
have read and understood the instructions, especially the
Safety chapter.
Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.