EN
9
dehumidifier TTK 175 S / TTK 355 S
Start-up
When positioning the device, observe the minimum distance
from walls or other objects as described in the chapter
Technical annex.
A
B
C
C
D
•
Before restarting the device, check the condition of the
power cable. If there are doubts as to the sound condition,
contact the customer service.
•
Only position the device in rooms where potentially leaking
refrigerant cannot accumulate.
•
Only position the device in rooms where there is no source
of ignition (e.g. open flames, an active gas appliance or an
electric heater).
•
Only put up the device in an upright, stable position on firm
ground.
•
Do not create tripping hazards when laying the power
cable or other electric cables, especially when positioning
the device in the middle of the room. Use cable bridges.
•
Make sure that extension cables are completely unrolled.
•
When positioning the device, keep a sufficient distance to
heat sources.
•
Make sure that no curtains or other objects interfere with
the air flow.
•
When positioning the device, particularly in wet areas,
secure it locally with an RCD (residual current device)
which complies with the respective regulations.
Inserting the air filter
Note
Do not operate the device without an air filter inserted
into the air inlet!
Without the air filter, the inside of the device will be
heavily contaminated. This could reduce the
performance and result in damage to the device.
•
Make sure that the air filter is installed before switching
the device on.
Inserting the condensation tank
•
Ensure that the float inside the condensation tank is
inserted correctly.
•
Ensure that the condensation tank is empty and inserted
correctly.
Installing the condensate pump (optional)
Info
If you use the device in combination with the
condensate pump via the TTKwic port and with the
Qube, the Qube should be switched on and ready for
use at all times to ensure the continuous operation of
the pump.
If the Qube's internal pump does not deliver, the
collected condensate in the Qube can flow back from
the container through the suction hoses.