EN

dehumidifier TTK 175 S / TTK 355 S

The device is optionally available with an operating element with
dual counter (see the image at the top right). The dual counter
registers both the operating hours and the energy consumption
and is certified according to the MID (Measuring Instruments
Directive 2004/22/EC). The kWh display is factory-calibrated
and may be used for accounting purposes. Contact your Trotec
customer service.
The 

Status

 LED (17) flashes once a second during normal

operation. If it flashes more frequently, lights up permanently or
does not light up at all, there might be a fault, see chapter
Errors and faults.

Condensate pump (optional)

18

No. Designation

Meaning

18

Condensate pump

button

Switching the condensate pump on
and off for draining residual water

The device can optionally be operated with a condensate pump
(see chapter Installing the condensate pump (optional)). Contact
your Trotec customer service.

Switching on and starting up the device

Info

Note that the device is only functional after three to five
minutes each time it is switched on or after the water
container has been inserted.

1. Ensure that the condensation drain hose is properly

connected to the device and is free of damage.

2. Position a sufficiently large container (at least 20 litres; we

recommend a 60-litre mortar tub) beside the device and
insert the hose end. Check the filling level of the container
regularly.

3. Make sure that the condensation drain hose is installed

with a continuous decline.

4. Insert the mains plug into a properly secured mains

socket.

5. Switch on the device at the mains switch (15).
6. Ensure that the mains switch (15) is lit.
7. Adjust the room humidity level with the rotary switch (14).

Continuous operation mode

In continuous operation mode, the device dehumidifies the air
constantly, regardless of the humidity. To start continuous
operation mode, set the rotary switch (14) to Max.

Operation with hose attached to the condensation
connection

For continuous operation or unattended dehumidification, please
connect the supplied condensation drain hose to the device.

ü

A suitable hose (diameter: 19 mm) is ready for use.

ü

The device is switched off.

1. Remove the condensation tank.

Summary of Contents for TTK 175 S

Page 1: ...TRT BA TTK175S TTK355S TC220617TTRT01 011 EN TTK 175 S TTK 355 S EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Page 2: ...indicates dangers to the life and health of persons due to electrical voltage Warning This signal word indicates a hazard with an average risk level which if not avoided can result in serious injury...

Page 3: ...bles outside of the device are protected from damage e g caused by animals Never use the device if electric cables or the power connection are damaged The mains connection must correspond to the speci...

Page 4: ...work require the support of additional persons the person trained in handling flammable refrigerants shall continuously supervise the work carried out The entire refrigerant circuit is a maintenance f...

Page 5: ...ger Refrigerant R454C H220 Extremely flammable gas H280 Contains gas under pressure may explode if heated P210 Keep away from heat sparks open flames and other ignition sources No smoking P381 Elimina...

Page 6: ...dehumidify rooms The fan sucks damp room air through the air inlet the air filter the evaporator and to the condenser located behind it The air is cooled at the cold evaporator until it is below the...

Page 7: ...the remaining condensate from the device and the condensation drain hose see chapter Maintenance Do not use the power cable to drag the device Only wheel the device on firm and level surfaces Please n...

Page 8: ...llowing storage conditions Only store the device in a room measuring more than 4 m2 Only position the device in rooms where there is no source of ignition e g open flames an active gas appliance or an...

Page 9: ...ke sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with an RCD residual current device which complies with th...

Page 10: ...10 EN dehumidifier TTK 175 S TTK 355 S 1 2 3 4 5...

Page 11: ...f energy consumption 14 Rotary switch Selection of relative room humidity 15 Mains switch Switching the device on and off Is illuminated when the device is switched on 16 Condensation tank LED Is disp...

Page 12: ...is only functional after three to five minutes each time it is switched on or after the water container has been inserted 1 Ensure that the condensation drain hose is properly connected to the device...

Page 13: ...tect e g the compressor from overheating Upper temperature limit 35 C 2 C Lower temperature limit 3 C 2 C If the ambient temperature exceeds or falls below these limits the device automatically switch...

Page 14: ...the power cable and mains plug for damage Check the on site fusing Check the filling level of the condensation tank and empty it if necessary The Condensation tank LED 16 must not light up Check the c...

Page 15: ...y a specialist company for cooling and air conditioning or by Trotec Note Wait for at least 3 minutes after maintenance and repair work Only then switch the device back on The device still does not op...

Page 16: ...ank and or drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign object...

Page 17: ...if heated P210 Keep away from heat sparks open flames and other ignition sources No smoking P381 Eliminate all ignition sources if safe to do so P403 Store in a well ventilated place The entire refrig...

Page 18: ...ith a neutral cleaning agent 3 Allow the filter to dry completely Do not insert a wet filter into the device 4 Reinsert the air filter into the device Emptying the condensation tank Info The compresso...

Page 19: ...tion tank LED 16 will be illuminated The compressor and fan will switch off Activities required after maintenance If you want to continue using the device Reconnect the device to the mains If you do n...

Page 20: ...Pa Air volume flow 580 m h 580 m h 1 000 m h Mains connection 220 240 V 50 Hz 110 230 V 50 Hz 220 240 V 50 Hz Power consumption max 0 6 kW 0 6 kW 1 3 kW Nominal current 2 8 A 5 7 2 7 A 6 A Fusing 10 A...

Page 21: ...EN 21 dehumidifier TTK 175 S TTK 355 S Wiring diagram With operating hours counter...

Page 22: ...22 EN dehumidifier TTK 175 S TTK 355 S With operating hours counter and MID counter...

Page 23: ...N 23 dehumidifier TTK 175 S TTK 355 S Exploded assembly drawing Info The position numbers of the spare parts differ from those describing the positions of the components mentioned in these instruction...

Page 24: ...rity pin 7 Left panel 24 Electronic controller 41 Rubber feet 8 Water tank baseplate complete set 25 Main switch 42 Control panel sticker 9 Structural foot 26 Electronic controller status LED 43 Axle...

Page 25: ...ur country The separate collection of waste electrical and electronic equipment aims to enable the re use recycling and other forms of recovery of waste equipment as well as to prevent negative effect...

Page 26: ...0 2003 A2 2009 EN 60335 2 40 2003 A11 2004 EN 60335 2 40 2003 A12 2005 EN 60335 2 40 2003 A13 2012 EN 60335 2 40 2003 AC 2006 EN 60335 2 40 2003 AC 2010 EN 60335 2 40 2003 AC 2013 EN 61000 3 3 2013 Ap...

Page 27: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: