background image

EN

3

dehumidifier TTK 165 ECO / TTK 170 ECO / TTK 380 ECO

Do not use the device with wet or damp hands.

Do not expose the device to directly squirting water.

Never insert any objects or limbs into the device.

Do not cover or transport the device during operation.

Do not sit on the device.

This appliance is not a toy! Keep away from children and
animals. Do not leave the device unattended during
operation.

Check accessories and connection parts for possible
damage prior to every use of the device. Do not use any
defective devices or device parts.

Ensure that all electric cables outside of the device are
protected from damage (e.g. caused by animals). Never
use the device if electric cables or the power connection
are damaged!

The electrical connection must correspond to the
specifications in chapter Technical data.

Insert the mains plug into a properly secured mains
socket.

Observe the device's power input, cable length and
intended use when selecting extensions to the power
cable. Completely unroll extension cables. Avoid electrical
overload.

Before carrying out maintenance, care or repair work on
the device, remove the mains plug from the mains socket.
Hold onto the mains plug while doing so.

Switch the device off and disconnect the power cable from
the mains socket when the device is not in use.

Do not under any circumstances use the device if you
detect damages on the mains plug or power cable. 
If the supply cord is damaged, it must be replaced by the
manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
Defective power cables pose a serious health risk!

When positioning the device, observe the minimum
distances from walls and other objects as well as the
storage and operating conditions specified in the Technical
data chapter.

Make sure that the air inlet and outlet are not obstructed.

Make sure that the suction side is kept free of dirt and
loose objects.

Do not remove any safety signs, stickers or labels from the
device. Keep all safety signs, stickers and labels in legible
condition.

Only transport the device in an upright position with an
emptied condensation tank or drain hose.

Discharge the collected condensate before transport and
storage. Do not drink it. Health hazard!

Intended use

Only use the device for drying and dehumidifying room air, while
adhering to and following the technical data.
Intended use comprises:

dehumidifying and drying:

– living rooms, bedrooms, bathrooms and basements
– laundries, holiday homes, camper vans, boats

maintaining the dryness of:

– storage spaces, archives, laboratories, garages
– bathrooms, wash rooms, changing rooms etc.

Improper use

The device is not intended for industrial use.

Do not place the device on wet or flooded ground.

Do not place any objects, e.g. clothing, on the device.

Do not use the device outdoors.

Any unauthorised modifications, alterations or structural
changes to the device are forbidden.

Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.

Personnel qualifications

People who use this device must:

be aware of the dangers that occur when working with
electric devices in damp areas.

have read and understood the instructions, especially the
Safety chapter.

Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.

Summary of Contents for TTK 165 ECO

Page 1: ...TRT BA TTK165ECO TTK170ECO TTK380ECO TC2017 16 003 EN TTK 165 ECO TTK 170 ECO TTK 380 ECO EN ORIGINAL INSTRUCTIONS DEHUMIDIFIER...

Page 2: ...ou can download the current version of the instructions and the EU declaration of conformity via the following link TTK 165 ECO https hub trotec com id 40461 TTK 170 ECO https hub trotec com id 40716...

Page 3: ...When positioning the device observe the minimum distances from walls and other objects as well as the storage and operating conditions specified in the Technical data chapter Make sure that the air in...

Page 4: ...ain The drier air thus conditioned mixes with the air in the room The humidity in the room where the device is positioned is reduced as air constantly circulates through the device Depending on the ai...

Page 5: ...3 4 10 11 12 13 TTK 380 ECO 5 6 9 7 TTK 380 ECO No Designation 1 Transport handle 2 Air inlet with air filter 3 Condensation tank behind cover 4 Feet 5 Air outlet 6 Power cable holder 7 Wheels 8 Air f...

Page 6: ...the device back on Acting contrary might lead to compressor damage and a malfunctioning device Any warranty claims will be voided in this case Storage Before storing the device proceed as follows Drai...

Page 7: ...ttom side of the device 4 4 4 3 Then mount the wheels Mounting the wheels TTK 165 ECO TTK 170 ECO Prior to initial start up the wheels and the axle must be attached to the device To do so please proce...

Page 8: ...ice to rest for 12 to 24 hours so the refrigerant can accumulate within the compressor Wait 12 to 24 hours before switching the device back on Acting contrary might lead to compressor damage and a mal...

Page 9: ...device keep a sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow When positioning the device particularly in wet areas secure it locally with...

Page 10: ...itching the device on or off 11 Indicator light Indication of full condensation tank 12 Operating hours counter Indication of operating hours 13 Hygrostat connection Connection for hygrostat operation...

Page 11: ...le hose diameter 12 mm is ready for use The device is switched off 1 Open the front cover 2 Remove the condensation tank 3 Guide the condensation drain hose through the hole in the device s bottom pan...

Page 12: ...use The device is switched off 1 Open the front cover 2 Remove the condensation tank 3 Connect the condensation drain hose to the connection inside the housing 4 Refit the condensation tank into the d...

Page 13: ...automatically redirects the hot gas to the evaporator and closes again after defrosting is completed so that drying operation can be continued via the regular refrigerant circuit Unlike air circulati...

Page 14: ...evice s permissible operating range according to the technical data Ensure that the relative room humidity complies with the technical data Check the air filter for dirt If necessary clean or replace...

Page 15: ...months at least annually Check the air inlets and outlets for dirt and foreign objects and clean if necessary X X Clean the exterior X X Visually check the inside of the device for dirt X X Check the...

Page 16: ...evice for dirt Check the air filter for dirt and foreign objects and clean or replace if necessary Replace the air filter Check for damage Check the attachment screws Test run Empty the condensation t...

Page 17: ...illuminate the openings of the device 3 Check the inside of the device for dirt 4 If you see a thick layer of dust have the inside of the device cleaned by a specialist company for cooling and air con...

Page 18: ...er a drain or sink 3 Rinse the tank with clear water Clean the tank regularly using a mild cleaning agent no detergent 4 Refit the condensation tank into the device Make sure not to damage the float w...

Page 19: ...oltage 220 240 V 50 Hz 220 240 V 50 Hz 220 240 V 50 Hz Max power input 0 9 kW 0 9 kW 1 15 kW Nominal current 3 6 A 4 2 A 5 2 A Recommended fusing 10 A 10 A 10 A Refrigerant R 410A R 410A R 410A Amount...

Page 20: ...20 EN dehumidifier TTK 165 ECO TTK 170 ECO TTK 380 ECO Wiring diagram TTK 165 ECO TTK 170 ECO...

Page 21: ...EN 21 dehumidifier TTK 165 ECO TTK 170 ECO TTK 380 ECO TTK 380 ECO...

Page 22: ...gulations Declaration of conformity The text below sets out the contents of the declaration of conformity The signed declaration of conformity can be found at https hub trotec com id 40461 Declaration...

Page 23: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: