Intended use
Only use the device
TGH 11 E
/
TGH 16 E
/
TGH 31 E
for
generating hot air in well-ventilated interior spaces or in roofed
outdoor areas protected from weather effects.
Do not use the device in windowless rooms below ground level.
Only use the device in rooms corresponding to the minimum
dimensions specified in the technical data.
•
The device is suited for heating large rooms such as tents,
warehouses, workshops, construction sites, greenhouses
or agricultural halls.
•
The device may only be used in rooms with sufficient fresh
air supply and exhaust discharge. The ventilation shaft
must have a cross-section of at least 25 cm
2
per kW
nominal heat output. It is determined based on the calorific
value. The minimum ventilation cross-section amounts to
250 cm
2
.
•
It is intended to be used without frequent site changes.
•
The device must only be fuelled by a propane-butane gas
mixture.
The device may only be used in certain countries of destination
whilst adhering to the technical data.
Improper use
•
The device MUST NOT BE USED FOR HEATING
HABITABLE ROOMS IN RESIDENTIAL BUILDINGS; FOR
THE USE IN PUBLIC BUILDINGS: OBSERVE NATIONAL
REGULATIONS.
•
The device must not be positioned or operated in areas
with a high risk of fires or in potentially explosive
atmospheres.
•
Do not place the device on wet or flooded ground.
•
Do not place any objects, e.g. clothing, on the device.
•
Do not use the device out of doors, unless under a roof.
•
The device must not be operated in rooms with an
insufficient combustion air supply.
•
The device must not be operated in rooms below ground
level (souterrain or the like).
•
Any unauthorised modifications, alterations or structural
changes to the device are forbidden.
•
Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.
Personnel qualifications
People who use this device must:
•
have read and understood the instructions, especially the
Safety chapter.
Safety signs and labels on the device
Note
Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.
Symbols
Meaning
This symbol located on the device indicates that it
is prohibited to place objects (such as towels,
clothes etc.) above or directly in front of the
device.
In order to avoid overheating and fire hazards, the
heater must not be covered.
A label with the following content provided in German and
English is attached to the device:
GB USE INSTRUCTIONS – IGNITION
1. Connect the gas pipe to the machine – IMPORTANT: left
threads are used. 2. Connect the following to the cylinder in this order: pressure reducer, gas pipe.
Open the gas. 3. Turn on the pressure reducer after the heater connected to the power cord. Turn
the heater power switch to position "I". Continuously depress the valve knob on the heater with
your right hand, keep depressing the spark knob on the other side with your left hand, stop until the
burner lights. Keep the valve knob depressed for at least 20 seconds after lighting the burner. After
20 seconds, release the valve knob.
STOPPING
1. Turn the gas supply OFF by turning LP cylinder
valve clockwise to close. 2. Keep the motor continue to function, after 20 seconds, turn the power
switch to "O" position, and disconnect the power cord.
GB WARNINGS:
- For further details, read the instruction handbook. - When igniting,
check if the fan turns correctly. - Place the appliance so that the hot air jet does not
reach inflammable objects. - This appliance is not designed for domestic use. - Shut
out the gas cylinder after use. - Do not move or handle the appliance while the
generator is operating. - The mobile generator may be used only on fire-proof floors.
- Place the gas cylinder in a protected position, behind the appliance. - Use I3P-I3B/
P gas only. - Unplug the generator from the electrical mains when not in use. - Keep
children and animals well away from the generator. - Use only away from
combustible materials and in a well ventilated area. - It is forbidden to use heater in
a basement and below the ground level.