EN
11
gas heater fan TGH 11 E / TGH 16 E / TGH 31 E
Operation
Info
Ensure the tightness of all connections.
Make sure that the fan operates properly.
The device must not be taken into operation unless
these conditions are met!
Switching the device on
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
Note
The fan must be running during operation. An idle fan
during operation might lead to overheating.
1. Open the valve at the gas cylinder.
2. Switch on the fan by setting the on/off switch (2) to
position
I
.
2
TGH 11 E / TGH 16 E
2
TGH 31 E
ð
The on/off switch (2) will be illuminated in red.
3. Leave the fan running for approx. 30 s.
4. Press and hold the push button for the gas valve (3) while
actuating the ignition button (6).
3
6
TGH 11 E / TGH 16 E
3
6
TGH 31 E
5. It may be necessary to actuate the ignition button (6)
repeatedly before the gas catches fire.
6. Hold onto the gas valve push button (3) for roughly another
10 s after the ignition has been successful.