Operating manual – fan heater TFH 20 E / TFH 22 E
Maintenance
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch off the device.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
•
Allow the device to cool down completely.
Warning of electrical voltage
Maintenance tasks which require the housing to be
opened must only be carried out by authorised
specialist companies or by Trotec.
Cleaning the housing
Warning of electrical voltage
Never immerse the device in water!
Clean the device with a soft, damp and lint-free cloth. Ensure
that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth. Wipe the housing dry
after cleaning.
Technical annex
Technical data
Parameter
Value
Model
TFH 20 E
TFH 22 E
Heating capacity
stage 1:
stage 2:
stage 3:
ventilation only
1000 W
2000 W
ventilation only
1000 W
2000 W
Air discharge velocity
2.8 m/s
2.8 m/s
Operating range
-15 °C to +85 °C
-15 °C to +85 °C
Mains connection
220-240 V / 50 Hz
220-240 V / 50 Hz
Max. power input
2000 W
2000 W
Nominal current consumption 8.7 A
8.7 A
Plug type
CEE 7/17
CEE 7/17
Cable length
1.2 m
1.2 m
Protection class
II /
II /
Type of protection
IP20
IP21
Overheating protection
85 °C
75 °C
Weight
0.8 kg
1 kg
Dimensions
(length x width x height)
120 x 210 x 260 (mm) 150 x 230 x 300 (mm)
Minimum distance to walls or
other objects
A: top:
B: rear:
C: side:
D: front:
50 cm
50 cm
50 cm
120 cm
50 cm
50 cm
50 cm
120 cm