7
EN
Operating manual – fan heater TFH 20 E / TFH 22 E
Operation
•
Avoid open doors and windows.
Control panel
TFH 20 E
1
2
3
TFH 22 E
1
2
3
No.
Designation
1
rotary control thermostat
2
operating light
3
function selector switch ventilation and heating levels
Switching the device on
Info
The operating light (2) will be illuminated as soon as
the power cable is plugged in and the tilt protection
switch (8) is activated.
Once you have completely installed the device as described in
the Start-up chapter, you can switch it on.
Setting the heating level
1. Set the function selector switch (3) to the desired ventilation
or heating level.
Position
Designation
0
OFF
cold air / ventilation
I
warm air (1000 W)
II
warm air (2000 W)
Info
Choose the smaller power stage e.g. for a smaller
room. Should it turn out to be insufficient, switch to the
higher level.
Setting the room thermostat
1. Select the desired room temperature via the stepless rotary
switch (1) of the room thermostat.
TFH 20 E
minimum
maximum
TFH 22 E
minimum
maximum
To find the ideal thermostat setting, please proceed as follows:
•
Set the thermostat control to maximum.
•
As soon as the desired temperature has been reached,
slowly turn the thermostat control back until the device is
switched off.
•
The device now automatically maintains the desired
temperature level.
The room thermostat controls the room temperature
automatically:
•
When exceeding the set value, both the heating and the
ventilation will be switched off.
•
When falling below the set value, both the heating and the
ventilation will automatically be switched back on.
Info