16
EN
vertical heater TAC XT 18 / TAC XT 27
3. Press the
Room temperature
button on the
HEPA filter
operation setpoint
screen.
4. Press the
°C-specification
button next to the
room
temperature
button to alter the room temperature on the
next screen via the arrow buttons.
5. Press the
°C-specification
button next to the
blow-out
temperature
button to alter the blow-out temperature on
the next screen via the arrow buttons.
6. Press the
°C-specification
button to alter the air volume
flow on the next screen via the arrow buttons.
7. Press the
Configuration
button on the
HEPA filter operation
setpoint
screen to save the settings.
8. Press the
Back
button to return to the
HEPA filter operation
configuration
screen.
9. Press the
Timer mode
button.
10. Press the
Off
or
On
button on the
Timer mode
screen to
deactivate or activate the timer.
ð
When the
On
button is activated, the timer starts
running once the device is switched on. When the set
time has elapsed, the device switches off. Press the
Min
specification
button to alter the operating time on the
next screen via the arrow buttons. Press the
Back
button twice to return to the
HEPA filter operation
configuration
screen.
ð
If the
Off
button is activated, the settings are
deactivated. Press the
Back
button to return to the
HEPA
filter operation configuration
screen.
11. Press the
Heating
button.
12. Press the
Room
or
Supply air
button in the
Heating
screen.
ð
If the
Room
button is activated, you can alter the room
temperature. Press the
°C specification
button to set the
temperature via the arrow buttons. The room
temperature is controlled automatically.
ð
If the
Supply air
button is activated, you can alter the
supply air temperature (temperature of the blown-out
air). Press the
°C specification
button to set the
temperature via the arrow buttons. The supply air
temperature is maintained at a constant level.
13. Press the
Back
button twice to return to the
HEPA filter
operation configuration
screen.
14. Press the
Regenerate filter
button.
ð
The following display opens.
Back
Filter regeneration
pre
Interval
post
Off
Off
Off
ð
The enabled buttons are shown in black.
15. Press one or several buttons to activate filter regeneration
as follows.
ð
pre: filter regeneration is carried out before air cleaning
operation.
ð
interval: filter regeneration is always carried out after a
certain air cleaning operating time. If this function is
activated, the set time will be shown on the screen.
ð
post: filter regeneration is carried out after air cleaning
operation.
Back
Filter regeneration
pre
Interval
post
Off
Off
Off
240 Min
Info
Combinations of all three settings are possible, as
shown on the screen below.
16. If
Interval
is selected, press the displayed time to adjust
the time using the arrow buttons or by entering it directly.
ð
During the regeneration process, the filter will be heated
to 100 °C; the interval is 30 minutes.
ð
The
warning light
(12) is illuminated in blue during
filter regeneration.
Warning
Do
not
switch off the device during filter regeneration!
17. Press the
Minutes specification
button to alter the minute
specification setpoint on the next screen.
18. Press the
Back
button twice to return to the
HEPA filter
operation configuration
screen.
19. Press the
Supply air limitation
button.
ð
The supply air temperature limitation is activated once
room temperature control has been selected.
20. Press the
Min
or
Max
button on the supply air limitation
screen.
21. Press the
°C specification
button to set the temperature on
the next screen via the arrow buttons.
22. Press the
Back
button twice to return to the
HEPA filter
operation configuration
screen.
23. Press the
Setpoints
button.
Summary of Contents for TAC XT 18
Page 25: ...EN 25 vertical heater TAC XT 18 TAC XT 27 Circuits TAC XT 18 ...
Page 26: ...26 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 27: ...EN 27 vertical heater TAC XT 18 TAC XT 27 ...
Page 28: ...28 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 29: ...EN 29 vertical heater TAC XT 18 TAC XT 27 ...
Page 30: ...30 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 31: ...EN 31 vertical heater TAC XT 18 TAC XT 27 ...
Page 32: ...32 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 33: ...EN 33 vertical heater TAC XT 18 TAC XT 27 ...
Page 34: ...34 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 35: ...EN 35 vertical heater TAC XT 18 TAC XT 27 ...
Page 36: ...36 EN vertical heater TAC XT 18 TAC XT 27 TAC XT 27 ...
Page 37: ...EN 37 vertical heater TAC XT 18 TAC XT 27 ...
Page 38: ...38 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 39: ...EN 39 vertical heater TAC XT 18 TAC XT 27 ...
Page 40: ...40 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 41: ...EN 41 vertical heater TAC XT 18 TAC XT 27 ...
Page 42: ...42 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 43: ...EN 43 vertical heater TAC XT 18 TAC XT 27 ...
Page 44: ...44 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 45: ...EN 45 vertical heater TAC XT 18 TAC XT 27 ...