22. Press the
Back
button twice to return to the
Comfort
heating configuration
screen.
Pest control
Note
Different pests require different approaches of pest
control. By variation of the temperature and by heating,
thermal pest control can be adapted to the pest
infestation and the room situation.
With the pest control function (PestControl) the pests in the
room where the device is installed are killed off.
1. Press the following buttons in the main menu to carry out
settings regarding the pest control function:
ð
Configuration
ð
Configuration
ð
Pest control configuration
ð
The following screen will appear, allowing you to carry
out settings regarding the pest control function:
Back
Fan control
Setpoints
Ramp
Configuration PestControl
2. Press the
Setpoints
button.
ð
The following screen is shown:
Back
60 °C
30 Min
Pest control setpoint
Target temperature
Treatment duration
Configuration
3. Press the
Target temperature
button in the
Pest control
setpoint
screen.
4. Press the
°C-specification
button to alter the target
temperature on the next screen via the arrow buttons.
5. Press the
Treatment duration
button.
6. Press the
Min specification
button to alter the treatment
duration on the next screen via the arrow buttons.
7. Press the
Configuration
button on the
Pest control setpoint
screen to save the settings.
8. Press the
Back
button to return to the
Pest control
configuration
screen.
9. Press the
Fan control
button.
10. Press the
% specification
button on the
Fan control
screen
to alter the fan setpoint via the arrow buttons on the next
screen.
11. Press the
Back
button to return to the
Pest control
configuration
screen.
12. Press the
Ramp
button to set the ramp for pest control.
ð
The following screen is shown:
12.3 °C/h
123 Min
Time-controlled
Increase
Ramp type
Off
Back
13. Press the
Time-controlled
or
Increase
button on the
Ramp
type
screen.
ð
If the
Time-controlled
button is activated, you can alter
the ramp time. Press the
Min specification
button to
alter the ramp time on the next screen via the arrow
buttons. After switching on the device, the room
temperature setpoint is increased from the current room
temperature at switch-on to the target temperature
within the ramp time set.
ð
If the
Increase
button is activated, you can also alter the
ramp time. Press the
Min specification
button to alter
the ramp time on the next screen via the arrow buttons.
The room temperature setpoint is raised with the
increase specified, starting from the current room
temperature at switch-on until the target temperature
has been reached.
14. Press the
Back
button twice to return to the
Pest control
configuration
screen.
HEPA filter operation
If HEPA filter operation is activated, the room air is purified with
the integrated H14 HEPA filter (optional).
1. Press the following buttons in the main menu to carry out
settings for HEPA filter operation:
ð
Configuration
ð
Configuration
ð
HEPA filter operation configuration
ð
The following screen will appear, allowing you to carry
out settings regarding HEPA filter operation:
Back
Setpoints
Supply air limitation
Heating
Timer operation
HEPA filter operation configuration
Filter regeneration
2. Press the
Setpoints
button.
ð
The following screen is shown:
Back
20 °C
20 °C
33%
Hepa filter operation setpoint
Room temperature
Outlet temperature
Fan
Configuration
Summary of Contents for TAC XT 18
Page 25: ...EN 25 vertical heater TAC XT 18 TAC XT 27 Circuits TAC XT 18 ...
Page 26: ...26 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 27: ...EN 27 vertical heater TAC XT 18 TAC XT 27 ...
Page 28: ...28 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 29: ...EN 29 vertical heater TAC XT 18 TAC XT 27 ...
Page 30: ...30 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 31: ...EN 31 vertical heater TAC XT 18 TAC XT 27 ...
Page 32: ...32 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 33: ...EN 33 vertical heater TAC XT 18 TAC XT 27 ...
Page 34: ...34 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 35: ...EN 35 vertical heater TAC XT 18 TAC XT 27 ...
Page 36: ...36 EN vertical heater TAC XT 18 TAC XT 27 TAC XT 27 ...
Page 37: ...EN 37 vertical heater TAC XT 18 TAC XT 27 ...
Page 38: ...38 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 39: ...EN 39 vertical heater TAC XT 18 TAC XT 27 ...
Page 40: ...40 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 41: ...EN 41 vertical heater TAC XT 18 TAC XT 27 ...
Page 42: ...42 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 43: ...EN 43 vertical heater TAC XT 18 TAC XT 27 ...
Page 44: ...44 EN vertical heater TAC XT 18 TAC XT 27 ...
Page 45: ...EN 45 vertical heater TAC XT 18 TAC XT 27 ...