Page 1: ...TRT BA TACECOII TC210927TTRT02 001 EN TAC ECO II EN ORIGINAL INSTRUCTIONS HIGH PERFORMANCE AIR PURIFIER...

Page 2: ...mbol indicates that you should wear eye protection Wear protective gloves Information marked with this symbol indicates that you should wear protective gloves Wear a protective mask Information marked...

Page 3: ...y unroll the extension cable Avoid electrical overload Before carrying out maintenance care or repair work on the device remove the mains plug from the mains socket Hold onto the mains plug while doin...

Page 4: ...a toy and does not belong in the hands of children Warning Risk of suffocation Do not leave the packaging lying around Children may use it as a dangerous toy Note Do not operate the device without an...

Page 5: ...cking materials which serve to protect the device during transport Should the device be damaged please contact the responsible dealer or manufacturer where the purchase was made Carefully tilt the dev...

Page 6: ...completely unrolled When positioning the device keep a sufficient distance to heat sources Make sure that no curtains or other objects interfere with the air flow Inserting the air filter Note Do not...

Page 7: ...H14 4 1200 m h H13 5 1400 m h H13 Max 1650 m h E12 At an air volume flow of more than 1000 m h the filter class of the H14 HEPA standard filter will be reduced All values are approximate and may vary...

Page 8: ...er service If necessary bring the device to an authorised specialist electrical company or to Trotec for repair Maintenance The device is designed for long hours of operation with minimum maintenance...

Page 9: ...e X Check for damage X Check the attachment screws X Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air filter...

Page 10: ...equipment e g protective mask protective glasses and gloves Note Prior to cleaning the interior protect the fan and further electrical components from water ingress with appropriate means Cleaning th...

Page 11: ...screws from the top of the device 2 Remove all 4 screws 3 Remove both hold down devices 4 Take off the discharge hood 1 from the device and carefully put the discharge hood aside 5 Remove the H14 HEPA...

Page 12: ...t 6 on both sides and pull out the air inlet towards the front of the device 2 Remove the air filter I III II 3 Insert the new air filter into the device Observe the installation direction The black f...

Page 13: ...ance efficiency H14 or H13 Prefilter for air filter G4 Z line EN 779 2002 75 coarse ISO 16890 Mains connection 220 240 V 50 60 Hz Average power consumption 0 14 kW for 900 m3 h air volume 0 75 kW maxi...

Page 14: ...14 EN high performance air purifier TAC ECO II Circuit diagram...

Page 15: ...nnection C14 L N PE 10A 250V AC with fuse holder 4 Fan TAC 15 PVC insulating cap designation 11987 5 Tower basalt grey 3 tower sheets basalt grey 16 Self adhesive sealing tape EPDM 7x2mm L 3450mm 6 Op...

Page 16: ...ary button black rotary button 4 Differential pressure controller DDW H50 200Pa 1000Pa 13 Signal light flashing LED pilot light 22mm yellow 5 Spacer sleeve M04 x 20 IG IG 14 Rocker switch green illumi...

Page 17: ...differ from those describing the positions of the components mentioned in these instructions No Spare part No Spare part 1 Hood T0000737 4 Velcro dot self adhesive 13 black 2 Hexagon screw DIN 933 M1...

Page 18: ...he components mentioned in these instructions No Spare part No Spare part 1 Silencer T0000706 5 Allen screw Liko DIN7380 1 M5x12 VZ galv black 2 Support plate T0000553 6 Washer DIN 125 A 5 3x 10x1 VZ...

Page 19: ...T0001516 12 Hexagon screw DIN 933 M5x45 VZ galv 4 Support T0001517 13 Detent edged washer 5 1 x 10 2 x 1 VZ galv 5 Connection T0001518 14 Detent edged washer 10 2 x 22 3 x 2 5 VZ galv 6 Bottom plate...

Page 20: ...ntioned in these instructions No Spare part No Spare part 1 Bottom housing T0000665 5 Self adhesive needle felt 20x1mm L 1880mm 2 Upper housing T0000746 6 Self adhesive needle felt 25x1mm L 1160mm 3 C...

Page 21: ...bers of the spare parts differ from those describing the positions of the components mentioned in these instructions No Spare part No Spare part 1 Fan fan TAC V 3 Protective grid bolt circle 206 6 or...

Page 22: ...agon socket countersunk screw DIN 7991 M 5x6 VZ galv 5 Heat shield plate T0001352 17 Hexagon nut self locking DIN 985 M5 VZ galv 6 Cylinder Allen screw DIN 912 M4x8 VZ galv 18 Washer DIN 125 A 5 3x 10...

Page 23: ...f the spare parts differ from those describing the positions of the components mentioned in these instructions No Spare part No Spare part 1 Insulation top part T0001357 4 Insulation top part T0001362...

Page 24: ...e position numbers of the spare parts differ from those describing the positions of the components mentioned in these instructions No Spare part No Spare part 1 Insulation T0001366 4 Bottom insulation...

Page 25: ...stances potentially contained in the equipment Declaration of conformity Declaration of conformity in accordance with the EC Machinery Directive 2006 42 EC Annex II Part 1 Section A We Trotec GmbH dec...

Page 26: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...