10
EN
high-performance air purifier TAC ECO II
Activities required before starting maintenance
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
•
Switch the device off.
•
Hold onto the mains plug while pulling the power cable out
of the mains socket.
Warning of electrical voltage
Tasks which require the device to be opened must
only be carried out by authorised specialist
companies or by Trotec.
Warning
Observe local provisions and regulations on hygiene
when cleaning. Protect yourself during cleaning and
maintenance work with suitable protective equipment
(e.g. protective mask, protective glasses and gloves).
Note
Prior to cleaning the interior, protect the fan and further
electrical components from water ingress with
appropriate means.
Cleaning the housing
Clean the housing with a soft, damp and lint-free cloth. Make
sure that no moisture enters the housing. Protect electrical
components from moisture. Do not use any aggressive cleaning
agents such as cleaning sprays, solvents, alcohol-based or
abrasive cleaners to dampen the cloth.
Visual inspection of the inside of the device for dirt
1. Remove the air filters.
2. Use a torch to illuminate the openings of the device.
3. Check the inside of the device for dirt.
4. If you see a thick layer of dust, clean the inside of the
device with a vacuum cleaner.
5. Reinsert the air filters.