background image

20

EN

air cooler PAE 31

Technical annex

Technical data

Parameter

Value

Model

PAE 31

Evaporation capacity

1100 ml/h

Air flow rate

1000 m³/h

Mains connection

220-240 V / 50 Hz

Nominal current consumption 0.3 A

Power consumption

60 W

Sound pressure level (1 m
distance)

55 dB(A)

Water tank capacity

6 l

Weight

5.5 kg

Dimensions (length x width x
height)

265 x 310 x 620 mm

Minimum distance to walls and
other objects:

top (A):

rear (B):

sides (C):

front (D):

100 cm
100 cm
100 cm
100 cm

Remote control batteries

Type CR 2032

Disposal

The icon with the crossed-out waste bin on waste

electrical or electronic equipment stipulates that this equipment
must not be disposed of with the household waste at the end of
its life. You will find collection points for free return of waste
electrical and electronic equipment in your vicinity. The
addresses can be obtained from your municipality or local
administration. You can also find out about other return options
that apply for many EU countries on the website 
https://hub.trotec.com/?id=45090. Otherwise, please contact an
official recycling centre for electronic and electrical equipment
authorised for your country.
The separate collection of waste electrical and electronic
equipment aims to enable the re-use, recycling and other forms
of recovery of waste equipment as well as to prevent negative
effects for the environment and human health caused by the
disposal of hazardous substances potentially contained in the
equipment.

In the European Union, batteries and accumulators must not be
treated as domestic waste, but must be disposed of
professionally in accordance with Directive 2006/66/EC of the
European Parliament and of the Council of 6 September 2006
on batteries and accumulators. Please dispose of batteries and
accumulators according to the relevant legal requirements.

Summary of Contents for PAE 31

Page 1: ...TRT BA PAE31 TC2021 09 001 EN PAE 31 EN OPERATING MANUAL AIR COOLER ...

Page 2: ...f conformity via the following link PAE 31 https hub trotec com id 45001 Safety Read this manual carefully before starting or using the device Always store the manual in the immediate vicinity of the device or its site of use Warning Read all safety warnings and all instructions Failure to follow the warnings and instructions may result in electric shock fire and or serious injury Save all warning...

Page 3: ... dirt and loose objects Do not remove any safety signs stickers or labels from the device Keep all safety signs stickers and labels in legible condition Only transport the device in an upright position with an emptied water tank Empty the water tank before transport and storage Do not drink the water Health hazard Note that high humidity levels may enhance the growth of biological organisms in the...

Page 4: ...the device will be heavily contaminated This could reduce the performance and result in damage to the device Behaviour in the event of an emergency 1 Switch off the device 2 In an emergency disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective device to the mains Information about the device Descri...

Page 5: ...unction 3 Filling level indicator of the water tank 4 Wheels 5 Transport handle with compartment for the remote control 6 Air inlet with air filter and evaporation filter 7 Water tank with locking clips 8 Air filter front 9 Evaporation filter front 10 Air filter right side 11 Evaporation filter side 12 Air filter left side 13 Ice packs 14 Remote control ...

Page 6: ...lug while pulling the power cable out of the mains socket When the device is not being used observe the following storage conditions dry and protected from frost and heat in an upright position where it is protected from dust and direct sunlight with a cover to protect it from invasive dust if necessary Place no further devices or objects on top of the device to prevent it from being damaged Remov...

Page 7: ...ns socket Note Fill the device with fresh drinking water only The water temperature must not exceed 40 C Info If possible change the water every 3 days to prevent bacterial growth Info Optionally you can put ice packs into the water tank for additional cooling Observe the following when using the ice packs Put the ice packs into a freezer for at least 4 hours before use Put the ice packs into the ...

Page 8: ...de Otherwise wipe it dry Inserting evaporation filter and air filter Note When set to air cooling mode the device must not be operated without the evaporation filter otherwise cooling will not work Note Do not operate the device without an air filter inserted into the air inlet Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result...

Page 9: ...tted ð The device starts automatically ð The device starts in ventilation mode The fan speed LED 16 of stage 1 and the ventilation LED 17 are illuminated Setting the operating mode The device comes with the following operating modes Air cooling Ventilation Air freshening Night mode Air cooling The air cooling mode can be switched on in addition during all other operating modes During air cooling m...

Page 10: ...ver to fan stage 1 after 30 minutes ð Fan stage 3 The device operates at fan stage 3 and switches over to fan stage 2 after 30 minutes After another 30 minutes have passed the device switches over to fan stage 1 Info If you activate air cooling an alarm signal will be emitted when the water tank is empty even in night mode Setting the timer The function can be set in addition in all operating mode...

Page 11: ... any work on the device remove the mains plug from the mains socket Do not touch the mains plug with wet or damp hands Hold onto the mains plug while pulling the power cable out of the mains socket Info If possible change the water every 3 days to prevent bacterial growth Note Fill the device with fresh drinking water only The water temperature must not exceed 40 C Put the ice packs into a freezer...

Page 12: ... on the outside Otherwise wipe it dry Shutdown Warning of electrical voltage Do not touch the mains plug with wet or damp hands Switch the device off Hold onto the mains plug while pulling the power cable out of the mains socket Empty and clean the water tank see chapter Maintenance Clean the device according to the Maintenance chapter Store the device according to the Transport and storage chapte...

Page 13: ...Check whether there are any objects blocking the pump inlet Make sure that the pump inlet is not blocked In case the pump does not operate despite a correctly filled water tank and activated air cooling mode the pump might be defective Please contact the customer service Water is leaking Check the device for leaks Check the water tank for tight fit The swing function is not working The swing funct...

Page 14: ... Test run X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Clean the water tank Check air inlets and outlets for dirt and foreign objects and clean if necessary Clean the exterior Visually check the inside of the device for dirt Check the air filter for dirt and foreign objects and clean if necessary Replacing the evaporation...

Page 15: ...cloth Make sure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Cleaning the water tank The water tank should be cleaned every 3 days if actively used Use household vinegar as cleaning descaling agent Observe the manufacturer s specificat...

Page 16: ...t the air filters are neither worn nor damaged The corners and edges of the air filters must not be deformed or rounded Before reinserting the air filters make sure that they are undamaged and dry 1 Remove the front air filter 8 from the device 8 2 Remove both side air filters 10 and 12 from the device 10 12 3 Clean the filters using a slightly damp soft lint free cloth If the filters are heavily ...

Page 17: ...ir filter Without the air filter the inside of the device will be heavily contaminated This could reduce the performance and result in damage to the device Note For an even distribution of water please make sure that the top section of the evaporation filter is positioned at the top The evaporation filter should be replaced in case of heavy soiling In standard operation the interval for replacing ...

Page 18: ...vice 9 3 Remove both side air filters 10 and 12 from the device 10 12 4 Remove both side evaporation filters 11 from the device 11 11 5 Dispose of used evaporation filters according to the national regulations 6 Insert the new side evaporation filters 11 into the device 11 11 ...

Page 19: ...12 back into the device 10 12 9 Reinsert the front air filter 8 back into the device 8 Activities required after maintenance If you want to continue using the device Reconnect the device to the mains If you do not intend to use the device for a considerable time Store the device according to the Transport and storage chapter ...

Page 20: ...vicinity The addresses can be obtained from your municipality or local administration You can also find out about other return options that apply for many EU countries on the website https hub trotec com id 45090 Otherwise please contact an official recycling centre for electronic and electrical equipment authorised for your country The separate collection of waste electrical and electronic equipm...

Page 21: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...

Reviews: