local air conditioner PAC 2010 E / PAC 2610 E

Improper use

Do not place the device on wet or flooded ground.

Do not place any objects, e.g. clothing, on the device.

Do not use the device outdoors.

Any unauthorised modifications, such as alterations or
structural changes to the device, are forbidden.

Any operation other than as described in this manual is
prohibited. Non-observance renders all claims for liability
and guarantee null and void.

Personnel qualifications

People who use this device must:

be aware of the dangers that occur when working with
electric devices in damp areas.

have read and understood the operating manual, especially
the Safety chapter.

Maintenance tasks which require the housing to be opened
must only be carried out by specialist companies for cooling and
air-conditioning or by Trotec.

Safety signs and labels on the device

Note

Do not remove any safety signs, stickers or labels from
the device. Keep all safety signs, stickers and labels in
legible condition.

The following safety signs and labels are attached to the device:

PAC 2010 E

PAC 2610 E

Follow the manual

This symbol indicates that the operating manual must
be observed.

Follow the repair manual

Disposal, maintenance and repair work of the
refrigerant circuit may only be carried out in
accordance with the manufacturer's specifications and
by persons having a certificate of qualification. 
A corresponding repair manual is available from the
manufacturer upon request.

!!! ACHTUNG !!!

 

1.

   Vor Inbetriebnahme 

MIND. 6 STUNDEN

 aufrecht und still 

stehen lassen! Das schützt den Kompressor, verlängert  
die Lebensdauer erheblich und verhindert so einen 
Verlust der Kühlleistung.

 

2.

   Das Klimagerät muss immer 

BESONDERS VORSICHTIG

  

auf den Boden  gestellt werden! Ansonsten können 
Mikrorisse in der Bodenplatte und der Kondensat wanne   
entstehen, was dazu führt, dass Kondenswasser auf den 
Boden tropft.

Für Schäden, die durch unsachgemäßen Gebrauch entstehen,

übernehmen wir 

KEINE GEWÄHRLEISTUNG!

!!! WARNING !!!

 

1.

  Before operation, stand upright and r e st for 

MIN 6 HOURS!

 

 

This protects  the compressor, greatly extending its life and 
preventing loss of cooling performance.

 

2.

   The air conditioner must always  be  placed  on the 

with 

CAUTION!

 Otherwise, microcracks may form in 

the bottom plate and the condensate pan, causing 
condensation to  drip  onto  the

For damages caused by improper use,  

WARRANTY WILL BE NULL AND VOID!

!!! ATTENTION !!! 

 

1.

  Avant la mise en service,laisser immobile en position 

verticale 

PENDANT AU MOINS 6 HEURES ! 

Cela protège 

le compresseur, prolonge sensiblement la durée de vie 
et évite ainsi une diminution des performances de 
refroidissement. 

 

2.

Le climatiseur doit toujours être posé sur le sol 

AVEC 

LES PLUS GRANDES PRÉCAUTIONS ! 

Sinon, des 

micro-fissures risquent de se former dans le socle ou le 
bac de récupération de l’eau de condensation, ce qui 
entraînerait que cette dernière coule sur le sol.

Toute utilisation incorrecte ou non conforme entraîne

L’EXTINCTION DE LA GARANTIE !

Summary of Contents for PAC 2010 E

Page 1: ...TRT BA PAC2010E PAC2610E TC2016 37 004 EN PAC 2010 E PAC 2610 E EN OPERATING MANUAL LOCAL AIR CONDITIONER...

Page 2: ...e EU declaration of conformity via the following link PAC 2010 E https hub trotec com id 40010 PAC 2610 E https hub trotec com id 40011 Safety Read this manual carefully before starting or using the d...

Page 3: ...conditioners filled with R290 Only position the device in rooms where potentially leaking refrigerant cannot accumulate Only position the device in rooms where there is no permanent source of ignition...

Page 4: ...icate of qualification A corresponding repair manual is available from the manufacturer upon request ACHTUNG 1 Vor Inbetriebnahme MIND 6 STUNDEN aufrecht und still stehenlassen Das sch tzt den Kompres...

Page 5: ...witch off the device 2 In an emergency disconnect the device from the mains feed in Hold onto the mains plug while pulling the power cable out of the mains socket 3 Do not reconnect a defective device...

Page 6: ...device Transport To make the device easier to transport it is fitted with wheels To make the device easier to transport it is fitted with a carry handle Before transporting the device observe the fol...

Page 7: ...stopper 1 x Retaining clip 1 x Remote control 2 x Power cable holder 3 x Screw 1 x Manual Unpacking the device 1 Open the cardboard box and take the device out 2 Completely remove the packaging 3 Full...

Page 8: ...reeled around the holding fixture Mounting the condensation drain hose optional The condensation drain hose serves as drip protection and if required for discharging remaining condensate The device is...

Page 9: ...ns of a clamping piece Inserting the air filter Note Do not operate the device without an inserted air filter Without an air filter the inside of the device will be heavily contaminated which could re...

Page 10: ...The side labelled TOP must face upwards Discharging exhaust air The exhaust air coming from the device contains waste heat from the room to be cooled For this reason it is recommended to discharge th...

Page 11: ...on of emitted humid air causing the device to overheat and shut down The dimensions of the exhaust air hose were especially made to fit the device Do not replace or extend the hose for it could cause...

Page 12: ...the fan stage Low lowest level Med medium level High highest level Auto automatic speed regulation 23 Fan stage LED Indicates the current fan stage Info An acoustic signal is emitted each time a setti...

Page 13: ...h to 10 h or in increments of 1 hour 11 h to 24 h Note Do not leave the operating device unattended in a freely accessible room with an activated timer Automatic switch on The device is switched off...

Page 14: ...isplay Indication of the target temperature during setting Indication of the number of hours during timer programming Indication of the operating mode Indication of the fan stage Indication of the sel...

Page 15: ...Please proceed as follows to activate the self cleaning function internal drying 1 Select the operating mode cooling or dehumidification 2 Press the X FAN button 28 on the remote control The X FAN in...

Page 16: ...e compressor does not start In cooling mode the compressor will only start at a room temperature of at least 16 C Check whether the overheating protection of the compressor has tripped Disconnect the...

Page 17: ...ripped overload protection of compressor Check whether the ambient conditions are outside the range specified in the technical data Wait until temperature and humidity level are back within the operat...

Page 18: ...sation tray and drain hose X Maintenance and care log Device type Device number Maintenance and care interval 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Check air inlets and outlets for dirt and foreign o...

Page 19: ...d place The entire refrigerant circuit is a maintenance free hermetically sealed system and may only be maintained or repaired by specialist companies for cooling and air conditioning or by Trotec Saf...

Page 20: ...The corners and edges of the air filters must not be deformed or rounded Before reinserting the air filters make sure that they are undamaged and dry 1 Remove the air filters from the device 2 Clean t...

Page 21: ...that the condensate can run off the hose must not be kinked nor should it have to overcome an uphill incline towards the drain 4 Let the condensate run until the condensation drain hose is completely...

Page 22: ...nt stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find collection points for free return of waste electrical and electronic equipment i...

Page 23: ...Trotec GmbH Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com...

Reviews: