EN
13
infrared radiant oil heater IRO 15
Error codes
The following error messages can be displayed on the segment
display:
Error message
Meaning
Remedy
F0
The device was not switched off
properly. When the mains plug was
disconnected, the on/off switch was in
the
I
position.
Remove the mains plug from the mains socket. Switch off the
device by setting the on/off switch to the
0
position. Plug the
mains plug into a suitable socket. Switch on the device by
setting the on/off switch to the
I
position.
F1
No fuel in the tank
Switch off the device and fill the tank as described in the
“Filling the tank” chapter.
The fuel is soiled.
Switch off the device and clean the tank as described in the
“Cleaning the tank” chapter.
The photo cell is soiled or damaged.
Switch off the device and clean the tank as described in the
chapter for “Cleaning the tank”.
The fuel filter is soiled.
Switch off the device and clean the fuel filter as described in
the “Cleaning the fuel filter” chapter.
Ignition fault
Switch off the device and call the customer service.
F2
Defective temperature sensor / cable
break
Switch off the device and call the customer service.
F3
The device is overheating
Switch off the device and wait until it has cooled down.
The tilt protection has tripped.
Place the device on a level and stable ground and restart it.
LO
Ambient temperature below -9 °C
Normal operation, no remedy required
CH
Continuous operation (55 °C)
Normal operation, no remedy required