![Trotec IRO 15 Original Instructions Manual Download Page 10](http://html.mh-extra.com/html/trotec/iro-15/iro-15_original-instructions-manual_1172035010.webp)
10
EN
infrared radiant oil heater IRO 15
Operation
The device may only be used by accordingly instructed persons.
Operating elements
11
12
13
14
No. Designation
11
Segment display
Indication of the current room
temperature during operation
Indication of the target temperature
during the temperature adjustment
12
Operation
display
Illuminated during operation.
13 On/off switch
For switching the device on and off
14
Room thermostat
rotary switch
For setting the target temperature
Switching the device on
The device continues to operate until the desired room
temperature is reached.
1. Set the on/off switch (13) to position
I
.
ð
The
Operation
display (12) is lit.
ð
The room temperature is shown on the
Segment
display
(11).
2. Set the
Room thermostat
(14) rotary switch to the desired
room temperature. This value should be higher than the
current room temperature.
ð
The target temperature is indicated on the
Segment
display
(11) while the temperature is adjusted.
ð
When the temperature has been adjusted, the
Segment
display
(11) blinks three times, then the room
temperature is shown again.
3. Ensure a successful ignition.
Shutdown
Warning of electrical voltage
Do not touch the mains plug with wet or damp hands.
Note
Damage to the device due to overheating!
Never switch off the device by pulling the mains plug.
This may lead to overheating!
Switch off the device properly. Do not pull the mains
plug before the fan motor has completely stopped.
1. Switch off the device by setting the on/off switch (13) to
position
0
.
2. Wait until the fan motor has come to a complete standstill.
3. Secure the device against inadvertent switch-on by pulling
the mains plug.
4. Allow the device to cool down completely.
Restart after troubleshooting
During initial start-up and after the fuel oil circuit has been
drained completely, the fuel oil supply to the nozzle may be
insufficient. In this case, the flame monitoring system will
respond and the device will be blocked. Please proceed as
follows:
1. Wait for approx. 1 minute.
2. Switch the device on.
If the device is still not starting, proceed as follows:
1. Make sure that there is fuel left in the tank.
2. Please refer to the chapters General safety warnings and
Errors and faults.