8
EN
infrared radiant oil heater IRO 15
Mounting the protective plate
Note
At delivery, the screws required for the installation are
already screwed into the housing.
1. Loosen the 2 screws on the front ring.
2. Push the 2 screws through the protective plate.
3. Screw the protective plate tightly to the the front ring using
the 2 screws.
Mounting the protective grid
1. Use 4 screws to mount the protective grid to the front of
the device.
Mounting the foot
Fasten the foot to the tank using 4 screws and secure the tank
using the 4 matching nuts.
Positioning
A number of spatial and technical conditions have to be
considered for the selection of the device's installation site.
Non-observance may impair the proper functioning of the device
or the accessories or can entail risks of personal injury and
property damage.
The following is to be observed for positioning:
•
Do not operate the device for more than 3 month at the
same place. Prior to planning the flue gas system, gather
information about the national legislation and contact a
responsible specialist.
•
The device may only be operated on roofed over surfaces.
•
The device is to be set up in a stable position on a
horizontal and incombustible ground.
•
The device must be set up in close proximity to a chimney,
an outer wall or on an open, ventilated surface.
•
The device must be connected to a properly secured mains
power socket.
•
The room where the device is positioned must be
sufficiently ventilated.
Ensure a sufficient fresh air supply, especially when there
are people or animals in the same room with the device!
•
The minimum distance between walls or other objects and
the air inlet opening of the device must be at least 1.5 m
(see figure).
There must be no walls or large objects near the device.