background image

17

EN

Operating manual – oil heater IDX 30 D

Wiring diagram

Summary of Contents for IDX 30 D

Page 1: ...TRT BA IDX30D TC 001 EN IDX 30 D EN OPERATING MANUAL OIL HEATER ...

Page 2: ...aterial damage but does not indicate hazards Info Information marked with this symbol helps you to carry out your tasks quickly and safely Follow the manual Information marked with this symbol indicates that the operating manual must be observed You can download the current version of the operating manual and the EU declaration of conformity via the following link IDX 30 D https hub trotec com id ...

Page 3: ... play with the appliance Cleaning and user maintenance shall not be made by children without supervision Do not use the device in potentially explosive rooms Do not use the device in aggressive atmosphere Set the device up in an upright and stable position Let the device dry out after a wet clean Do not operate it when wet Do not use the device with wet or damp hands Do not expose the device to di...

Page 4: ...any work on the device remove the mains plug from the mains socket Hold onto the mains plug while pulling the power cable out of the mains socket Warning of flammable substances Handling fuels entails a risk of fire Take sufficient precautions when handling fuels such as fuel oil kerosene or diesel Do not spill any diesel kerosene or fuel oil Do not inhale the vapours nor swallow any fuel Avoid sk...

Page 5: ...the sucked in cold air past a combustion chamber Inside the combustion chamber the fuel is burned The sucked in air is heated and fed back to the environment via the air outlet The fuel is conducted from the tank to the injection via a pump An ignition contact at the injection ignites the fuel which is then burned in a continuous flame Device depiction IDX 30 D THERMOST AT CONT ROL ROOM TEMP CLOSE...

Page 6: ...he mains socket When the device is not being used observe the following storage conditions dry and protected from frost and heat in an upright position where it is protected from dust and direct sunlight with a cover to protect it from invasive dust if necessary Assembly and installation Scope of delivery 1 device 1 transport handle 2 wheels 2 wheel caps 1 axle 2 locking rings 1 frame 4 small scre...

Page 7: ...nd property damage The following is to be observed for positioning The device may only be operated on roofed over surfaces The device is to be set up in a stable position on incombustible ground The device must be set up in close proximity to a chimney an outer wall or on an open ventilated surface The device must be connected to a properly secured mains power socket The room where the device is p...

Page 8: ...may only be used by accordingly instructed persons Operating elements 25 30 3 5 40 4 5 5 10 1 5 20 13 14 15 16 No Designation 13 Operating LED 14 Temperature indication 15 ON OFF switch 16 Rotary control thermostat Switching the device on The device continues to operate until the desired room temperature is reached 1 Set the on off switch 15 to position I ð The operating light 13 is illuminated 2 ...

Page 9: ...n tank or fuel Please contact the customer service Faulty electrical connection between transformer and mainboard Please contact the customer service Faulty electrical connection at the ignition electrodes Defective ignition Please contact the customer service The fan does not start even though the device is connected and switched on The operating light flashes Thermostat setting is too low Turn u...

Page 10: ... fuel Please contact the customer service Power failure In the event of a power failure the ignition is extinguished the device switches off immediately After a power failure the device will not restart automatically it has to be started via the on off switch There is a fuel leak Leak at drain screw Check the drain screw for tight fit and retighten it if necessary Check the sealing at the drain sc...

Page 11: ...cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth Filling the tank The fuel tank cap and the filling level indication are located to the left of the control panel ü Before attempting to fill the tank wait until the device has cooled down completely ü Only use fuel suitable for the device see technical data 1 Position the device on firm level and incombustible ground 2...

Page 12: ... Dispose of the fuel according to national regulations Cleaning air filters and fan The two air filters should be checked cleaned and possibly replaced approx every 500 operating hours The fan ought to be checked for dirt at least once per heating season This activity can be carried out along with the inspection of the air filters Overview of air filters The filter housing consists of the followin...

Page 13: ...art of the housing THERMOSTAT CONTROL ROOM TEMP CLOSE OPEN IDX 30 D Cleaning the fan blades 1 Carefully clean the fan blades with a soft damp and lint free cloth Ensure that no moisture enters the housing Protect electrical components from moisture Do not use any aggressive cleaning agents such as cleaning sprays solvents alcohol based or abrasive cleaners to dampen the cloth THERMOSTAT CONTROL RO...

Page 14: ...ing with filters and sealing Removing filters for cleaning or replacement 1 Remove the two filters from the filter housing 33 30 31 32 33 2 Check both filters for dirt or damage Replace the prefilter 31 if needed If required clean the foam filter 32 using a slightly damp soft lint free cloth If the foam filter is heavily contaminated clean it with warm water mixed with a neutral cleaning agent ...

Page 15: ...s into the device 4 Insert both filters into the filter housing 33 Ensure the proper seating of the seal 30 30 31 32 33 Assembling the filter housing 1 Attach the filter housing with filters and sealing 2 Tighten the hexagonal bolts at the filter housing 3 Fasten the pressure gauge in place 0 6 0 8 1 0 0 2 0 4 ...

Page 16: ...r part of the housing on the device THERMOSTAT CONTROL ROOM TEMP CLOSE OPEN IDX 30 D 2 Tighten the 8 screws at the upper part of the housing IDX 30 D THERMOSTAT CONTROL ROOM TEMP 0 6 0 8 1 0 0 2 0 4 CLOSE OPEN 3 Attach the protective grid IDX 30 D 4 Tighten the 4 screws at the protective grid IDX 30 D ...

Page 17: ... operation by means of a slotted screwdriver For lowering turn the screw counter clockwise for increasing carefully turn it clockwise 0 6 0 8 1 0 0 2 0 4 Technical annex Technical data Parameter Value Article number 1 430 000 066 Method of heating direct Amount of air 735 m h Fan Axial fan Nominal heat output 30 kW 25 800 kcal Temperature increase ΔT 90 C 1 5 m distance Input voltage 230 V 50 Hz C...

Page 18: ...17 EN Operating manual oil heater IDX 30 D Wiring diagram ...

Page 19: ...8 Operating manual oil heater IDX 30 D Spare parts drawing and list Info The position numbers of the spare parts differ from those describing the positions of other parts mentioned in this operating manual ...

Page 20: ...tor Kit 15 Fixation Part 36 Ignitor Wire 5 5 Blade 16 Fuel Tank 37 Photocell 5 6 End Pump Cover 17 Supporting Bracket 38 Photocell Bracket 5 7 Output Filter small 18 Power Cord 39 Fuel Gauge Disposal The icon with the crossed out waste bin on waste electrical or electronic equipment stipulates that this equipment must not be disposed of with the household waste at the end of its life You will find...

Page 21: ......

Page 22: ...Trotec GmbH Co KG Grebbener Str 7 D 52525 Heinsberg 49 2452 962 400 49 2452 962 200 info trotec com www trotec com ...