Draining the tank
25 30
35
40
45
5
10
15
20
1. Provide for a suitable collection container.
2. Move the device to an elevated position.
3. As indicated in the figure use a wrench to open the screw at
the bottom of the tank.
4. Drain the fuel into the collection container.
5. When no more fuel is discharged, seal the drain hole again.
ð
Ensure the tight fit of the screw and, if required, replace
the seal, for otherwise fuel might leak out
uncontrollably.
6. Dispose of the fuel according to national regulations.
Cleaning air filters and fan
The two air filters should be checked, cleaned and possibly
replaced approx. every 500 operating hours.
The fan ought to be checked for dirt at least once per heating
season. This activity can be carried out along with the
inspection of the air filters.
Overview of air filters
The filter housing consists of the following parts:
•
filter seal (30)
•
prefilter (31)
•
foam filter (32)
•
filter housing (33)
30
31
32
33
Opening the housing
In order to check the fan and the air filters you will first have to
remove the protective grid and then the upper part of the
housing:
1. Loosen the 4 screws at the protective grid.