Installation, Operating, Maintenance
and After Sales Manual.

Product Serial Number: 

Please leave this manual with the end user.

heating

through

innovation.

HI-LINE LV Fan Convector
Model: 7-4

01.02.2010  ISSUE 3

Part Number: 1370058
Issue 3

xxxxxx HiLine LV manual_Layout 1  27/06/2011  09:39  Page 2

Summary of Contents for 7-4

Page 1: ...perating Maintenance and After Sales Manual Product Serial Number Please leave this manual with the end user heatingthroughinnovation HI LINE LV Fan Convector Model 7 4 01 02 2010 ISSUE 3 Part Number 1370058 Issue 3 ...

Page 2: ...it Selection Sizing 03 4 0 Location 03 5 0 Preparation 04 6 0 Fixing 04 7 0 Water Connections 04 8 0 Electrical Connection 05 9 0 Commissioning Procedure 05 10 0 Technical Data 06 11 0 Operating Instructions 06 12 0 Troubleshooting 06 13 0 Maintenance 07 Contents ...

Page 3: ... heating system For optimum fan convector heating performance the system must be capable of providing sufficient hot water through the heat exchanger This means that 1 The minimum pipe size from boiler to fan convector must be at least 15mm 2 This unit is not suitable for use on microbore pipe work 3 Where the unit is fitted on to a system with other emitters a separate circuit for the fan convect...

Page 4: ...ing dimensions below see fig 2 mark the fixing hole positions on the wall l Drill and plug the wall for No 8 x 40mm round head wood screws ensuring that the wall plugs are suitable for the wall type l Remove the backing from the self adhesive washers and place on screws with adhesive side towards the point l Tighten the screws into the wall leaving about 9mm projecting l Press adhesive washers to ...

Page 5: ...ong mains cord l A fused electrical spur with a maximum 3A fuse and a switch having 3mm separation on all poles must be provided in an easily accessible position The fused spur must not be positioned in a bathroom or other similar high humidity installations l For bathroom installations this unit must be connected to an equipotential bond using the pipe clamp provided in the accessories pack Attac...

Page 6: ...ted to a high setting Set fan speed control to position I The unit will now run on low fan speed The low speed setting is recommended for normal operation with the high speed for boost heating position II when required Low Limit Operation A low limit thermostat fitted to the HI LINE LV will ensure that the fan stops after the heating system is switched off and the water flow stops If left in an op...

Page 7: ...ermostat Poor water flow Heating Mode poor heating performance and or unit cycles on low limit thermostat Possible Causes Boiler thermostat set too low Lack of flow to fan convector Pump set on low setting Isolating valves not fully open System incorrectly balanced with unit starved of hot water flow Pipe sizing to unit too small Problem Poor heating performance Unit incorrectly sized for heat los...

Page 8: ...t Yorkshire HU9 5PE T 01482 713927 F 01482 789056 service convectors myson co uk Spare parts and technical help on all Convector products are available from MYSON Service MYSON Eastern Avenue Team Valley Gateshead Tyne Wear NE11 0PG UK T 0845 402 3434 F 0191 491 7568 sales myson co uk www myson co uk ...