Operating manual – IDS 65 D
B-2
EN
Risk of burns! Persons present in the installation area must ob-
serve a minimum distance of 2 meters to the heating unit! Warn-
ing signs must alert of the source of danger.
Avoid the improper use of fuels.
Risk of environmental pollution!
Do not let any leaked fuel seep away into the soil and prevent it
from entering the sewer system.
5. Function and product characteristics
The oil heating unit IDS 65 D is used to heat up room air in order to
achieve a fast heating of well ventilated rooms.
The oil heating unit is operated with heating oil. The device features an
indirect combustion. This means that the warm air and the combustion
gases are released into the surrounding area.
A selection of two operating modes ensures that the oil heating unit can
be controlled both manually by the user as well as automatically with the
support of the thermostat.
6. Technical data
Type IDS 65 D
Parameter
Value
Article number
1.430.000.025
Electrical connection
230 V
Frequency
50 Hz
Nominal current max.
2.6 A
Power consumption
598 W
Air volume
2500 m³/h
Fan
Axial fan
Nominal heat load max.
65 kW
Nominal heat output
-
Temperature increase T
1)
-
Oil consumption max.
4.65 l/h
Tank capacity
65 l
Air transportation hose connection
2)
-
Chimney connection
-
Thermostat connection
series
Combustion
direct
Nozzle
Delavan 1.25-80° S (gal/h)
Pump pressure
16 bar
Gap between electrodes
Setting of air flap a=
20 mm
Setting of air flap A=
8 °
Sound pressure level (at distance
of 1 m)
71 dB (A)
Length
1200 mm
Width
555 mm
4. General safety instructions
Please observe the following safety instructions!
Any non-compliance with these instructions may
have serious consequences for the health of per-
sons and could result in property damage and
damage to the environment.
Risk of explosion!
Do not operate the device in potentially flammable or explosive
environments. Do not install it in such environments, either.
Do not place the device on a flammable surface.
Remove any inflammable materials and chemicals from the im-
mediate operating environment.
Functional impairment of and damage to the device!
Do not use the device outdoors.
Install the device in a stable position.
Keep the intake and exhaust openings free.
Do not cover the device during operation.
Only disconnect the device from the mains once it has cooled
down completely.
Do not use any chemicals for cleaning the device.
Risk of injury and damage to property due to defective devices!
Before each use of the device, check its accessories and connec-
tion parts for possible damages. Do not use any defective devices
or device parts.
Do not use the device if you detect any damage to its plug and
cables. Defective power cables represent a serious health threat.
Danger to life through electrical shock!
Only connect the device to power sources that are in good tech-
nical order. Do not use damaged wall outlets!
Pull the connection cable out of the wall outlet by pulling it at
its plug.
Do not touch electrical connection cables when your hands are wet!
Protect the electrical connection cables against damage caused
by, for example, animals.
Do not carry out any changes or repairs on the device!
Do not expose the device to any liquids.
Do not apply any liquids to the interior of the device. If this does
happen nevertheless, pull out the power cord and have the de-
vice checked by a specialist workshop.
Risk of injury!
Do not insert any objects into the intake and exhaust opening of
the device.
Do not reach into the existing openings.
Do not leave children or animals unattended near the operating
device!
Do not operate the device in rooms with insufficient supply of
combustion air.