oxygen regenerator Zerozon 200
Recording of the operating time
The operating hours counter (
3
) indicates the duration the
device has already been in operation.
The number of elapsed operating hours can be used for the
calculation of the energy consumption. Use the following
formula:
0.11 kW/h x operating hours.
The result will be no more than an approximate value of the
average consumption. For the precise determination of the
current consumption you can additionally install an ammeter
between device and energy source.
Shutdown
Warning
Risk of injury caused by ozone!
Have especially trained staff check the ozone
concentration before entering the room and permitting
others to access it.
Warning
Wear a respirator mask with ozone filter when you
check whether the ozone concentration has decreased
sufficiently by means of a suitable measuring device.
When combined with an ozone generator, the device has been
designed a way that the ozone generator is automatically
switched off after the set time has elapsed. A corresponding
function was integrated by way of a timer.
Switch off the device by actuating the
On/Off
button (
18
).
Available accessories
Warning
Only use accessories and additional equipment
specified in the instructions.
Using insertion tools or accessories other than those
specified in the instructions may cause a risk of injury.
Designation
Article number
Filter set
7.710.000.392
Ozone warning sign
ZZ7000275
Oz-One (ozone meter)
3.510.006.110
Errors and faults
The device has been checked for proper functioning several
times during production. If malfunctions occur nonetheless,
check the device according to the following list.
The device does not start:
•
Check the power connection.
•
Check the power cable and mains plug for damage.
•
Check the on-site fusing.
•
Wait for 10 minutes before restarting the device. If the
device is not starting, have the electrics checked by a
specialist company or by Trotec.
The device is loud or vibrates:
•
Check whether the device is set up in a stable and upright
position.
The device gets very warm, is loud or is losing
performance:
•
Check the air inlets and air filters for dirt. Remove external
dirt.
The device gives off an unpleasant odour:
•
Smoke, e.g. dense tobacco smoke, odours and
contaminations may be in the air. Ventilate the room.
The device still does not operate correctly after these
checks:
Please contact the customer service. If necessary, bring the
device to an authorised specialist electrical company or to
Trotec for repair.