TABLE 9
Power Options / Consumption
Specification
Value
Antenna protection
<= 0.5
μ
J for 3kA @ 8/20
μ
S Waveform
EN61000-4-2 Level 4 ESD Immunity
EN61000-4-5 Level 4 Surge Immunity
Data Port Protection
EN61000-4-2 Level 4 ESD Immunity
EN61000-4-5 Level 4 Surge Immunity
AC Power
Single Phase VAC
100-480 VAC 50/60 Hz; 23W/60W
IEEE/ANSI C62.41 CAT C Power Source
IEC Category IV Power Source
AC Input Protection
EEE/ANSI C62.41 Category C 10kA @8/20uS Waveform; 36kA per
phase L-L, L-N, L-PE
EN61000-4-2 Level 4 ESD Immunity
EN61000-4-5 Level 4 Surge Immunity
EN61000-4-4 Level 4 EFT Immunity
Integrated Branch Circuit Protection
Class CC-Fuse: Littlefuse KLDR Time-
Delay 20A
Integrated Branch Circuit Protec-
tion
Class CC-Fuse: Littlefuse KLDR Time-Delay 20A