Page 12 of 15
24-Feb-12
Configuration
Configuration of the 1410-B is covered in the current version of the Tropos User Guide for Release 7.9 or
higher.
Recommended Testing
Tropos recommends that the OEM integrator perform the following tests to validate the integration of
the 1410-B into their product. These are provided as guidelines to the OEM. Actual testing is the
responsibility of the OEM.
Physical Installation and Packaging
1.
Verify that the 1410-B is installed in the enclosure in accordance with the assembly drawings
and the installation guidelines and specifications provided in this document.
2.
Verify that the antennas are properly connected to the SMA-antenna connectors.
3.
Verify that the cable connecting the 1410-B to the OEM equipment is properly installed.
4.
Verify that the 1410-B is powered when power is provided to the power supply board.
5.
Verify that the external LED (if used) is properly wired and operates correctly.
Figure 3 shows a typical test configuration
1410-B
OEM
communicating
device
coax cables to
antenna
connectors
DNP3 serial data plus
DC power or Ethernet
plus power
power supply
7320 gateway
RF
combinerer
60dB RF
attenuator
Communications
processor if
required
20 dB
attenuator
20 dB
attenuator
50Ω
50Ω
50Ω
Figure 3
Typical Test Configuration