8
special piping requirements
for users of ultrapure water
Ultrapure water users have reported that over time,
exposure to ultraviolet light may photochemically
degrade nonmetallic piping materials, including most
or all fluoro-polymers, resulting in material break-
down and/or structural failure. Should your water
application and piping material be so classified, we
recommend you install “UV light traps” to isolate any
such susceptible material from direct exposure to the
ultraviolet light. Install the UV light traps to the inlet/
outlet of the UV treatment chamber prior to the connec-
tion of any nonmetallic materials. UV light traps protect
nonmetallic piping. Should you require additional
assistance, please contact your local Aquafine
representative or the factory directly.
more
If the location of the UV unit
is vacant for 3 or more days,
the UV unit should be
unplugged to prevent
overheating. After plugging
in the UV unit from a cold start, it takes
about 3 minutes for the lamp to warm up to
100% UV power.