background image

Thermostatic electric shower

26

Triton Showers 

Triton Road 

Nuneaton 

Warwickshire  CV11 4NR

Triton is a division of Norcros Group (Holdings) Limited

TRITON reserve the right to change product specification without prior notice. E&OE. © TRITON SHOWERS 2012

Customer Service: 

0844 980 0750

Trade Installer Hotline: 

0844 980 0730 

Fax: 

 

0844 980 0744

www.tritonshowers.co.uk 

E-mail: [email protected]

Extended Warranty AVAILABLE NOW. Call 0844 980 0740 for more details.

TrITon STandard GuaranTEE

Triton guarantee this product against all 

mechanical and electrical defects arising from 

faulty workmanship or materials for a period of 

two years for domestic use only, from the date of 

purchase, provided that it has been installed by 

a competent person in full accordance with the 

fitting instructions. 
Any part found to be defective during this 

guarantee period we undertake to repair or replace 

at our option without charge so long as it has been 

properly maintained and operated in accordance 

with the operating instructions, and has not been 

subject to misuse or damage. 
This product must not be taken apart, modified or 

repaired except by a person authorised by Triton. 

This guarantee applies only to products installed 

within the United Kingdom and does not apply to 

products used commercially. This guarantee does 

not affect your statutory rights. 

What is not covered: 
1.

  Breakdown due to: 

a)

 use other than domestic 

use by you or your resident family; 

b)

 wilful act 

or neglect; 

c)

 any malfunction resulting from the 

incorrect use or quality of electricity, gas or water 

or incorrect setting of controls; 

d)

 failure to install 

in accordance with this installation guide. 

2.

  Repair costs for damage caused by foreign 

objects or substances.

3.

  Total loss of the product due to non-availability 

of parts.

4.

  Compensation for loss of use of the product or 

consequential loss of any kind.

5.

  Call out charges where no fault has been found 

with the appliance.

6. 

Call out charges where the water supply cannot 

be isolated, this includes consequential losses 

arising from unserviceable supply valves.

7. 

The cost of repair or replacement of pressure 

relief devices, showerheads, hoses, riser rails 

and/or wall brackets, isolating switches, 

electrical cable, fuses and/or circuit breakers or 

any other accessories installed at the same time.

8. 

The cost of routine maintenance, adjustments, 

overhaul modifications or loss or damage arising 

therefrom, including the cost of repairing 

damage, breakdown, malfunction caused by 

corrosion, furring, pipe scaling, limescale, 

system debris or frost.

3-1-2012

uK SErVICE PoLICY

In the event of a product fault or complaint occurring, the following 

procedure should be followed:

1. 

Telephone Customer Service on 

0844 980 0750

 having available, 

your details including post code, the model number and power 

rating of the product, together with the date of purchase and, where 

applicable, details of the particular fault.

2. 

If required, the Customer Service Advisor will arrange  

for a qualified engineer to call.

3.

  All products attended to by a Triton service engineer must be 

installed in full accordance with the Triton installation guide 

applicable to the product. 

(Every product pack contains an installation 

guide, however, they can also be bought via our Customer Service Spares 

Department)

.

4.

  Our engineer will require local parking and if a permit is required this 

must be available to the engineer on arrival at the call. 

5.

  It is essential that you or an appointed representative 

(who must 

be over 18 years of age)

 is present for the duration of the service 

engineer's visit. If the product is in guarantee you must produce 

proof of purchase.

6.

  Where a call under the terms of guarantee has been booked and 

the failure is not product related 

(i.e. scaling and furring, incorrect 

water pressure, pressure relief device operation or electrical/plumbing 

installation fault)

 a charge will be made. A charge will also be issued 

if nobody is at home when the service engineer calls or adequate 

parking/permit is not available.

7.

  If the product is no longer covered by the guarantee an up front 

fixed fee will be charged before the site visit.

8.

  Should proof of purchase not be available on an “in-guarantee” call, 

or should the service engineer find that the product is no longer 

under guarantee, the engineer will charge the same fixed price and 

the customer will be expected to pay the engineer before he leaves. 

If payment is not made on the day an administration charge will be 

added to the fixed charge.

9.

  If a debt is outstanding from a previous visit, or from any other Triton 

purchase. Triton reserves the right to withhold service until the debt 

has been settled.

10.

  Triton takes the health, safety and wellbeing of its employees very 

seriously and expects customers to treat all staff members with respect. 

Should any employee feel threatened or receive abuse, either verbally 

or physically, Triton reserves the right to withhold service and will 

support the employee with a legal prosecution.

replacement Parts Policy

It is the policy of Triton Showers to maintain parts availability for the 

duration of production and a period of 5 years thereafter in accordance 

with industry standards. In the event of a spare part not being available a 

substitute part will be supplied.
Spare parts can be ordered via our online spare parts store, or by 

telephoning Triton Spares Department. Payment should be made by 

credit/debit card 

(excluding American Express or Diners Card)

. Payment 

can also be made by pre-payment of a pro-forma invoice, by cheque or 

postal order.
Telephone orders are based on information given during of the call. 

Before contacting Triton, please verify your requirements using the 

information contained in the user guide. Triton cannot accept liability for 

incorrect part identification.

Summary of Contents for Topaz T100si

Page 1: ...INSTALLERS PLEASE NOTE THESE INSTRUCTIONS ARE TO BE LEFT WITH THE USER 2180360p November 2011 Topaz T100si thermostatic control electric shower Installation and operating instructions...

Page 2: ...he cover 13 Operating the shower 14 Operating functions 17 Cleaning 19 Instructions for installers and service engineers only 20 21 Spare parts 22 23 Fault finding 24 25 Guarantee service policy etc r...

Page 3: ...unit will result in higher temperatures and could also cause the PRD Pressure Relief Device in the unit to operate 1 9 This product is not suitable for mounting into steam rooms or steam cubicles 2 P...

Page 4: ...ied person and in the sequence of this instruction book Care taken during the installation will provide a long trouble free life from your shower SPECIFICATIONS Electrical Nominal power Nominal power...

Page 5: ...Earth connection 10 PRD 11 Solenoid valve 12 Trimplate 13 Thermostatic valve 14 Scale trap 15 Pressure switch 16 Shower outlet 17 Guide pockets Inside cover fig 2 18 Control printed circuit board 19 S...

Page 6: ...re fuse way which will take the fuse or Miniature Circuit Breaker MCB necessary for the shower Fig 4 4 1 If your consumer unit has a rating below 80A or if there is no spare fuse way then the installa...

Page 7: ...8 The current carrying capacity of the cable must be at least that of the shower circuit protection see Table B 8 1 To obtain full advantage of the power provided by the shower use the shortest cable...

Page 8: ...ult a competent plumber Under site conditions where the power supply is below 220 volts and the mains water pressure is above 5 bar it is recommended to fit a pressure reducing valve set at 3 5 bar A...

Page 9: ...ich has an optimum viewing angle that is slightly below eye level Therefore position the unit so the display is at nose level For multiple users of varying heights an optimum shower height must be arr...

Page 10: ...shower is positioned over a bath or shower tray because if the PRD operates then water will eject from the bottom of the unit Should this happen turn off the electricity and water supplies to the show...

Page 11: ...from the rear or bottom the centre of the inlet valve to the wall surface is 21 mm fig 10 Note If entry is from the rear the nut of the compression fitting will be partially behind the surface of the...

Page 12: ...ff the water supply either at the mains stopvalve or the isolating stopvalve Connect the mains water supply to the inlet fig 12 of the shower via 15 mm copper stainless steel or plastic pipe using a 1...

Page 13: ...routing through conduit or in trunking or by embedding in the wall in accordance with current IEE regulations The use of connections within the unit or other points in the shower circuit to supply pow...

Page 14: ...o position so that the control spindle locates correctly the flats only allow the spindle and knob only fit one way Should any difficulty arise recheck the points above While applying slight pressure...

Page 15: ...sure the pipe and cable entering the unit do not prevent the cover locating correctly to the backplate d Make sure the valve spindle has the flat and keyway slot uppermost 12 o clock position e Make s...

Page 16: ...lay shows FUL fig 20 indicating full power is being used After a few seconds two up arrows start flashing indicating the unit is working towards its preset showering temperature fig 21 This is achieve...

Page 17: ...the same temperature as before Note If the setting was high at full power then it will not be possible to obtain the same temperature on economy power The shower will try to provide the highest tempe...

Page 18: ...fig 27 position all inner segments full that corresponds to the control position To decrease the shower temperature Turn the temperature control anti clockwise the current temperature display is repla...

Page 19: ...ean the showerhead or not The shower will then reset automatically for a further preset number of shower operations before flashing the reminder again Low pressure When the display backlight turns red...

Page 20: ...e of the fault and replace the safety device once the unit has been repaired Changing the fascia This shower unit has the facility for the coloured fascia to be simply changed for another colour of yo...

Page 21: ...y affect the product surface finish and invalidate your guarantee It is important to keep the showerhead clean to maintain the performance of the shower The hardness of the water will determine the fr...

Page 22: ...son Switch off the electricity supply at the mains Remove the cover The inlet filter is situated in the solenoid inlet fig 54 and can be removed to clean To gain access to the filter will require the...

Page 23: ...omplete with O rings Be aware of water discharging as the heater can exhausts Clean out the trap and remove all sediment Flush the can through by leaving the cap off and switching on the power at the...

Page 24: ...or 9 5kW 22010310 Restrictor 10 5kW 22010410 5 Solenoid valve assembly and O ring 83307110 6 Pressure Relief Device 82800450 7 Trimplate 7052989 8 Can brace 7053008 9 Thermostatic valve and O rings 4...

Page 25: ...set 2 x earth 1 x solenoid wires 83307150 Power PCB carrier 7052991 Rubber microswitch cover 7063046 Inlet filter 7053009 16 Coloured fascias Seaspray TSTZFSEA Aqua TSTZFAQU Azure TSTZFAZU Lilac TSTZF...

Page 26: ...Unit malfunction 2 2 1 Contact Customer Service 3 Water too hot 3 1 Temperature control incorrect setting 3 1 1 Turn anti clockwise 3 2 Unit malfunction 3 2 1 Contact Customer Service 4 Unstable show...

Page 27: ...or flashing 6 4 Blocked connecting tube to pressure switch 6 4 1 Make sure the tube from solenoid valve to pressure switch is not kinked or blocked 7 Water continues to flow when unit is isolated at i...

Page 28: ...umber and power rating of the product together with the date of purchase and where applicable details of the particular fault 2 If required the Customer Service Advisor will arrange for a qualified en...

Page 29: ...Showers Power Showers Smart Showers Shower Towers From Top Shower Brands Mira Showers Aqualisa Showers Triton Showers Gainsborough Showers Shower Pumps can upgrade your showering experience even more...