Concentric thermostatic mixer valve
18
FIttInG tHE contRoLS
Built in and Exposed
Fit the controls using the following procedure:
•
(fig.9-a)
Fit washer A and then the flow
control lever so that it is in the 12 o’clock
position.
•
(fig.9-b)
Fit the washer B and then the
maximum temperature stop.
The end of the thin outer raised edge should
be around 2mm above the 3 o’clock position
with the grub screw fitting positioned on
the left hand side. Once the maximum
temperature stop in place, tighten the
retaining grub screw.
•
(fig.9-c)
Fit the temperature control,
making sure the maximum temperature
stop pin is as close to the flat edge of the
temperature stop as possible
(the button
should be at the 3 o’clock position, as a guide)
.
Secure the temperature knob in place with
the retaining screw and fit the end trim.
Fig.9
2mm above 3 o’clock
a.
b.
c.
3 o’clock
position
12 o’clock
position
3 o’clock position
Retaining
grub screw
Washer A
Washer B