background image

In the event of a product fault or complaint occurring, 
the following procedure should be followed:
DO NOT REMOVE THE PRODUCT

1.  Telephone Customer Service on 

024 7637 2222

 having 

available your details including post code, the model number 
and power rating of the product, together with the date of 
purchase and, where applicable, details of the particular fault.

2.  If required, the Customer Service Advisor will arrange for a 

qualifi ed engineer to call.

3.  All products attended to by a Triton service engineer must be 

installed in full accordance with the Triton installation guide 
applicable to the product. (Every product pack contains an 
installation guide, however, they can also be downloaded free at 
www.tritonshowers.co.uk). 

4.  Our engineer will require local parking and if a permit is 

required, this must be available to the engineer on arrival at the 
call.

5.  It is essential that you or an appointed representative (who must 

be over 18 years of age) is present for the duration of the service 
engineer’s visit. If the product is in guarantee you must produce 
proof of purchase.

6.  Where a call under the terms of guarantee has been booked 

and the failure is not product related (i.e. scaling and furring, 
incorrect water pressure, pressure relief device operation or 
electrical/plumbing installation fault) a charge will be made. A 
charge will also be issued if nobody is at home when the service 
engineer calls or adequate parking/permit is not available.

7.  If the product is no longer covered by the guarantee an 
 

up-front fi xed fee will be charged before the site visit.

8.  Your receipt must be retained as proof of purchase. Should proof 

of purchase not be available on an ‘in-guarantee’ call, or should 
the service engineer fi nd that the product is no longer under 
guarantee, the engineer will charge the same fi xed price and the 
customer will be expected to pay the engineer before he leaves. 
If payment is not made on the day an administration charge will 
be added to the fi xed charge.

9.  If a debt is outstanding from a previous visit, or from any other 

Triton purchase, Triton reserves the right to withhold service until 
the debt has been settled.

10.  Triton takes the health, safety and wellbeing of its employees 

very seriously and expects customers to treat all staff members 
with respect. Should any employee feel threatened or receive 
abuse, either verbally or physically, Triton reserves the right to 
withhold service.

Replacement Parts Policy

In line with AMDEA guidelines, Triton retains functional spares 
for as long as there is a market for them and in most cases, well 
beyond.  Due to the vast array of product types, the life cycle of 
products can vary and therefore so can the length of time parts 
can be supplied. Spare parts can be ordered via our online spare
parts store or by telephoning Triton Customer Service Spares
Department on 

024 7637 2222

. Payment should be made by

credit / debit card (excluding American Express or Diners Card).
Payment can also be made by pre-payment of a pro-forma
invoice, by cheque or postal order.

Telephone orders are based on information given during 
the call.  Before contacting Triton, please verify your 
requirements using the Information contained in the
user guide. Triton cannot accept liability for incorrect part 
identifi cation. 

TRITON STANDARD GUARANTEE

With the exception of accessories, Triton guarantee the
product against all manufacturing defects for a period of 

5 years

 (for domestic use only) from the date of purchase, 

provided that it has been installed by a competent person in 
full accordance with the fi tting instructions. 
All accessories such as shower heads, hoses and riser rails 
carry a 

1 year

 parts only guarantee against manufacturing 

defects.
Any part found to be defective during this guarantee period 
we undertake to repair or replace at our option without 
charge, so long as it has been properly maintained and
operated in accordance with the operating instructions and 
has not been subject to misuse or damage. This product must 
not be taken apart, modifi ed or repaired except by a person 
authorised by Triton. This guarantee applies only to products 
installed within the United Kingdom and does not apply to 
products used commercially.  This guarantee does not affect 
your statutory rights.

What is not covered:

1.  Breakdown due to:  

a) 

use other than domestic use by you or your resident 

family; 

b)

 wilful act or neglect; 

c) 

any malfunction resulting from the incorrect use or 

quality of electricity, gas or water or incorrect setting of 

controls; 

d) 

failure to install in accordance with this installation 

guide.

2.  Claims for missing parts once the product has been 

installed.

3.  Repair costs for damage caused by foreign objects or 

substances.

4.  Total loss of the product due to non-availability of parts.
5.  Compensation for loss of use of the product or 

consequential loss of any kind.

6.  Call out charges due to an abortive visit or where no fault 

has been found with the appliance.

7.  The cost of repair or replacement of isolating switches, 

electrical cable, fuses and/or circuit breakers or any other 

accessories installed at the same time. Replacement of the 

Pressure Relief Device that only activates when the shower 

outlet is blocked is also excluded. 

8.  The cost of routine maintenance, adjustments, overhaul 

modifi cations or loss or damage arising therefrom, 

including the cost of repairing damage, breakdown, 

malfunction caused by corrosion, furring, frost or 

exposure to freezing conditions.

9.  Call out charges where the water supply cannot be 

isolated, this includes consequential losses arising from

 

unserviceable supply valves.

For the latest Terms & Conditions please see:

www.tritonshowers.co.uk/terms

Triton Showers
Triton Road
Nuneaton
Warwickshire, CV11 4NR

Triton is a division of Norcros Group (Holdings) Limited

Customer Service: 024 7637 2222

Trade Installer Hotline: 024 7637 8344

www.tritonshowers.co.uk

E-mail: [email protected]

E-mail: [email protected]

UK SERVICE POLICY

TRITON reserve the right to change product specifi cation without prior notice. E&OE. © TRITON SHOWERS 2018

Summary of Contents for Bar Mixer Shower With Diverter

Page 1: ...ower With Diverter Installation and operating instructions The showerhead and hose supplied with this product are a safety critical part of your shower Failure to use genuine Triton parts may cause injury and invalidate your guarantee ...

Page 2: ...2 3 INTRODUCTION 4 5 TYPICAL DOMESTIC INSTALLATIONS 6 7 SITING OF THE SHOWER 8 PREPARING THE MIXER VALVE 8 INSTALLING THE BAR MIXER BRACKET 8 FITTING THE BAR MIXER 8 11 OPERATING THE SHOWER 12 LEAK TESTING 13 COMMISSIONING 13 TEMPERATURE ADJUSTMENT 14 ADJUSTING THE MAXIMUM TEMPERATURE SETTING 14 SPARE PARTS 15 16 MAINTENANCE 17 FAULT FINDING 18 19 GUARANTEE SERVICE POLICY ETC rear cover Installers...

Page 3: ...ar mixer shower 1 A B C D MAIN COMPONENTS E A Thermostatic mixer valve B Riser pipe C Bracket D Wall Bracket E Fixed head pipe F Slider G Hose not shown H Handset not shown I Fixed showerhead not shown F ...

Page 4: ...Bar mixer shower 2 DIMENSIONS 131 96 111 45 150 283 ...

Page 5: ...r mixer shower 3 IMPORTANT All dimensions listed in this fitting book regarding the product and installation are approximate Consideration must be given for the adequate ceiling space 400 730 1127 55 75mm ...

Page 6: ...ient to meet all normal requirements and will minimise the effects of scale in hard water areas Pressure reducing valve On sites where the running pressure is above 5 bar the use of a suitably sized pressure reducing valve fitted in the cold mains supply pipe work can provide nominally equal pressures at the mixer shower Water minimum flow rate For best performance within the specified running pre...

Page 7: ...plications For commercial applications in line filters are recommended Hard water areas a If it is intended to operate the shower in areas of hard water above 200 ppm temporary hardness a scale inhibitor may have to be fitted For advice on the scale inhibitor please contact Customer Service b For best performance the showerhead MUST be regularly cleaned to remove scale and debris WATER SYSTEM REQU...

Page 8: ... valve MUST be fitted if the supply pressures exceed 5 bar running An expansion vessel MAY be fitted and regularly maintained to prevent the shower mixer being damaged by excess pressures This may already be installed within the boiler check with manufacturer and is in addition to the normally larger central heating expansion vessel Fig 2 diagrammatic view not to scale Fig 1 diagrammatic view not ...

Page 9: ...ight pressure reducing valve when the mains pressure is over 5 bar The drop tight pressure reducing valve must be set at the same value as the unvented package pressure reducing valve Note An additional expansion vessel may be required if a second pressure reducing valve is installed This does not apply to packages with a cold take off after the pressure reducing valve to the cylinder Mains pressu...

Page 10: ...ould be positioned as detailed with all controls within comfortable reach of the user The handset can be positioned above or to either side of the shower INSTALL BAR MIXER BRACKETS Guidance on installing the bar mixer brackets fig 6 can be found in a separate instruction book supplied Please read the instructions carefully Read through the whole of this guide before beginning installation The wall...

Page 11: ...ce of the valve fig 7 Once the diverter has been fitted and faces forward fully tighten the small retaining grub screw located at the rear of the diverter assembly fig 8 FITTING THE MIXER SHOWER Offer the shower valve to the bar mixer brackets check that the sealing washers are in place and carefully tighten the nuts Care must be taken not to damage the chrome plated surface fig 9 Fig 7 Fig 8 Fig ...

Page 12: ...making sure the bracket engages the hexagonal fitting and the O ring is in place fig 11 Using a suitable screwdriver tighten the retaining screw to secure the rail into the support Screw the bottom part of the rail to the upper section and tighten Note The upper and lower riser pipework MUST not be cut The product may not perform within stated specifications if altered Alterations may invalidate t...

Page 13: ...ITTING THE HOSE AND HANDSET Connect one end of the flexible hose to the bottom outlet connector fig 15 on the diverter valve making sure that the sealing washer is in place Screw the other end of the hose to the handset then locate the handset into the handset holder Screw the fixed head to the riser fixed head rail Make sure the sealing washer is in place and screw tight to seal the joint Importa...

Page 14: ...e On Off flow control left hand side fig 16 TEMPERATURE CONTROL To adjust the water temperature rotate the temperature control right hand side clockwise for cool or anti clockwise for hot fig 17 To overcome the maximum temperature stop press the override button and turn Fig 17 Fig 16 ...

Page 15: ... and at or near to their design temperature and pressures and are within the requirements stated in the site requirements Make sure the temperature control right hand side is at the maximum temperature setting Allow the shower to run at this maximum temperature setting until the water temperature has stabilised Rotate the temperature control until your desired showering temperature is reached IMPO...

Page 16: ...s of 41 C for showers The mixed water temperatures must never exceed 46 C The British Burns Association recommends 37 C to 37 5 C as a comfortable bathing temperature for children WARNINGS Exposed metal surfaces may become hot during use Fig 19 Adjusting the maximum temperature override setting Remove the temperature control by removing the end cap and unscrewing the retaining screw fig 19 Turn th...

Page 17: ...Bar mixer shower 15 SPARE PARTS Ref Description Part No 1 Control Knobs 86005110 2 Flow Control Cartridge 83316680 3 Thermostatic Cartridge 83316190 4 Diverter cartridge 83316690 4 3 2 1 1 1 ...

Page 18: ...Bar mixer shower 16 Ref Description Part No 8 Lower shower arm 88400039 9 Bracket 22013588 10 Upper shower arm 88400041 11 Slider 22013510 12 Hose 28100300 10 8 9 12 11 ...

Page 19: ... maintenance of the internal of the valve will depend mainly on the water supply condition Experience of local conditions will dictate the intervals for inspection and in service testing guidance has been given below which can be adjusted for local requirements a Initially check the filters for debris once every three months and clean if necessary b Perform a thermal shut off test every three mont...

Page 20: ... 17 0 19 5 22 0 Pressure bar 0 1 0 2 0 3 0 4 0 5 1 0 2 0 3 0 4 0 5 0 Conditions for test Inlet temperatures comply with EN1111 requirements Outlet temperature 38C Flow control fully open Open outlet No hose or shower head connected Important Product flow rates are for guidance only ...

Page 21: ...Bar mixer shower 19 ...

Page 22: ...eat ing system 2 5 Hot water supply blocked or restricted 2 6 Flow regulator not fit ted HP systems only 3 1 Flow regulators not fitted 1 1 1 Refer to commissioning section 1 2 1 Reposition temperature control knob 1 3 1 Reposition temperature control knob 1 4 1 Turn off the shower and consult a compe tent plumber or contact Moretti Customer Service 1 5 1 Reduce the simultaneous demand from the su...

Page 23: ...r company 4 2 1 Inspect the inlet filters Clean if necessary 4 3 1 Turn off the shower and consult a suitably competent plumber 4 4 1 Clean showerhead 4 5 1 Reduce the simultaneous demand 4 5 2 Make sure stop service valves are fully open 4 5 3 Check if sufficient water pressure 5 1 1 Fit a pressure reducing valve 6 1 1 Fit a pressure reducing valve 7 1 1 Renew flow control cartridge 4 Water does ...

Page 24: ...ners Card Payment can also be made by pre payment of a pro forma invoice by cheque or postal order Telephone orders are based on information given during the call Before contacting Triton please verify your requirements using the Information contained in the user guide Triton cannot accept liability for incorrect part identification TRITON STANDARD GUARANTEE With the exception of accessories Trito...

Reviews: