DIVERTER CONTROL
The diverter fitted to this product has two
position settings.
The first position allows the user to select the
‘overhead’ shower head and the second position
selects the ‘hand held’ shower head.
The positions are selected by rotating the handle
clockwise or anticlockwise
(fig.18)
.
LEAK TESTING
Fit the hose to the outlet and direct it to waste.
Open the isolating valves to the shower and
check for leaks. Remedy any leaks found.
COMMISSIONING
• Start the water flow by rotating the flow
control (left hand side).
• Make sure that the hot and cold water
supplies are fully open and at (or near to)
their design temperature and pressures, and
are within the requirements stated in the site
requirements.
• Make sure the temperature control (right hand
side) is at the maximum temperature setting.
• Allow the shower to run at this maximum
temperature setting until the water
temperature has stabilised.
• Rotate the temperature control until your
desired showering temperature is reached.
IMPORTANT
The temperature adjustment range must be
checked to guarantee user safety.
• Rotate the temperature control checking
the minimum and maximum showering
temperatatures; ADJUST THE MAXIMUM
TEMPERATURE STOP SETTING if required.
• The following is recommended for domestic
installations but must be carried out for
commercial installations. Perform a thermal
shut off test described within the maintenance
section