Bar mixer shower
11
RISER KIT INSTALLATION
• Slide the Diverter collar and Rubber seal
(making sure the tapered part of the seal is
at the bottom)
over the base of the riser
rail assembly and fit into the outlet of the
diverter
(fig.13)
.
• Carefully locate the rail holder into the
wall bracket
(fig.14)
. Secure in place by
tightening the grub screw in the bracket.
• Tighten the diverter collar.
FITTING THE HOSE AND HANDSET
• Connect one end of the flexible hose to the
bottom outlet connector
(fig.15)
on the
diverter valve, making sure that the sealing
washer is in place.
• Screw the other end of the hose to the
handset then locate the handset into the
handset holder.
• Screw the fixed head to the riser/fixed head
rail. Make sure the sealing washer is in place
and screw tight to seal the joint.
Important
It is the conical end of the hose which grips into
the holder. The showerhead will not fit in the
holder without the hose attached.
Fig.13
Fig.14
Fig.15
Grub screw
Washers
Showerhead