22
- XM095 V1.2 NR
Gobo wheel 2 Er
(Gobo wheel 2
- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The Gobo wheel 2 is not located in the default position after the reset.
Gobo Rot 2 Er
(Gobo Rot 2- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The Gobo Rot 2 is not located in the default position after the reset.
Prism Er
(Prism- error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction
(sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Prism
is not located in the default position after the reset.
Focus Er
(Focus error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction
(sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Focus
is not located in the default position after the reset.
Iris Er
(Iris error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction
(sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Iris is
not located in the default position after the reset.
Zoom Er
(Zoom error) This message will appear after the reset of the fixture if the magnetic-indexing circuit malfunction
(sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main PCB). The Zoom
is not located in the default position after the reset.
Animation Er
(Animation error) This message will appear after the reset of the fixture if the magnetic-indexing circuit
malfunction (sensor failed or magnet missing) or the stepping-motor is defective (or its driving IC on the main
PCB). The Animation is not located in the default position after the reset.
CLEANING AND MAINTENANCE
The following points have to be considered during the inspection:
1) All screws for installing the devices or parts of the device have to be tightly connected and must
not be corroded.
2) There must not be any deformations on the housing, color lenses, fixations and installation spots
(ceiling, suspension, trussing).
1)
Mechanically moved parts must not show any traces of wearing and must not rotate with
unbalances.
2)
The electric power supply cables must not show any damage, material fatigue or sediments.
Further instructions depending on the installation spot and usage have to be adhered by a skilled
installer and any safety problems have to be removed.
Note:
If the external flexible cable or cord of this device is damaged, it shall be exclusively
replaced by the manufacturer or his service agent or a similar qualified person in order to
avoid a hazard.