background image

32

Triplett Model 9310-A

10: MAINTENANCE

Your Triplett Model 9310-A Digital Clamp Meter is a precision measuring instru-
ment and, when used as described in this manual, should not require mainte-
nance. There are no internal user serviceable parts (fuses, etc).

However, periodic calibration of the meter will insure that it is accurate and per-
forming in accordance with its design specifications. A one year calibration inter-
val is suggested.

To clean the outside of the meter, use a cloth dampened with a mild detergent
solution. Do not use any abrasive cleansers, or chemical solvents that may dam-
age the case of the meter.

  TRIPLETT PRODUCT RETURN INSTRUCTIONS

  In the unlikely event that you must return your Triplett equipment for repair,
  the following steps must be taken.

  1)  Call 1-800-TRIPLETT to obtain a Return Material
       Authorization (RMA) number from Customer Service.

  2)  Enclose a copy of the original sales receipt showing date of purchase.

  3)  Clearly print the RMA number on the outside of the shipping container.

  4)  Return to:

Triplett Corporation
One Triplett Drive
Bluffton, OH 45817
ATTN: Repair Dept.

Be sure to include a full description of the problem, and a telephone number,
street address, or email address, where you can be contacted, and a return ad-
dress where the meter can be shipped to upon repair.

Summary of Contents for 9310-A

Page 1: ...Clamp On Ammeter and Multi tester It performs the basic electrical measure ments required by the homeowner as well as advanced measurements useful to the professional electrician It measures AC and D...

Page 2: ...n damage to the meter or injury to the user 2 5 Follow the recommendations of any Trade Organizations or Regulatory Agencies whose scope encompasses the use of this meter Failure to do so may result i...

Page 3: ...ed in the instructions for performing particular tests Inserting the test leads in incorrect jacks can damage the meter and or injure the user 2 14 Do not exceed the maximum voltage or current limitat...

Page 4: ...o the user 2 24 Use caution when working with voltages above 25 volts AC or 35 volts DC Such voltages may cause a life threatening electrical shock 2 25 This meter is not for use by children Failure t...

Page 5: ...when using this meter to measure voltages in industrial appli cations where the High Energy circuitry is used High Energy circuitry is usually regarded as any circuitry capable of supplying over 4000...

Page 6: ...other probe you could receive a shock Failure to observe this precaution may result in damage to the meter or injury to the user 2 43 To avoid damage to the meter and possible user injury disconnect t...

Page 7: ...ld damage the meter leading to user injury 2 48 Do not use the meter if there is evidence of chemical leakage from the battery Leakage could damage meter and lead to injury of user 2 49 Observe whethe...

Page 8: ...ith Manual Overide 4 3 AC and DC Current Measurements Clamp On to 1000A 4 4 38mm 1 5 max conductor diameter 32mm 1 3 jaw opening 4 5 AC and DC Voltage Measurements to 600V CAT III 4 6 Resistance Measu...

Page 9: ...Humidity less than 90 5 9 Case Dimensions 219 x 84 x 45 mm L x W x H 8 63 x 3 31 x 1 75 inches L x W x H 5 10 Weight 338 grams 0 75 lbs w battery w o leads 5 11 Battery 1 standard 9 volt alkaline batt...

Page 10: ...6 V 1 D S L 3 g d r 5 1 e c n a d e p m I t u p n I M 0 1 s e g n a r l l A M 0 0 1 n a h t r e t a e r g s i e g n a r V m 0 0 4 t p e c x e y c n e u q e r F z H 0 0 4 o t z H 0 4 I I I T A C n o i...

Page 11: ...r e v O x a m c e s 0 3 r o f S M R C A r o C D V 0 0 6 g n i d a e r o r e z l a u d i s e r L E R F n 0 1 w o l e b e t a r u c c a t o N y c n e u q e r F e g n a R n o i t u l o s e R y c a r u c...

Page 12: ...12 Triplett Model 9310 A FIGURE 1 FRONT PANEL OF 9310 A 1 2 3 4 6 9 11 12 13 10 5 7 8 Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Page 13: ...test lead is plugged into this jack for all measurements except current amps To avoid electrical shock or instrument damage do not connect this jack to any source that is more than 600V with respect...

Page 14: ...DETAILS Refer to Figure 2 to identify the various display annunciators AUTO The Auto ranging annunciator is on when the meter is set to a function that has multiple ranges available In most of these f...

Page 15: ...is active Percent Annunciator This annunciator is displayed whenever the Duty Cycle mode is active F Fahrenheit Annunciator This annunciator is displayed whenever the Temperature measurement mode is...

Page 16: ...s These annunciators are displayed whenever Frequency is being measured The displayed annunciator indicates the range of frequency that is being measured FIGURE 3 OVERLOAD INDICATION Overload Indicati...

Page 17: ...attery Cover Screw This screw secures the battery cover 15 Battery Cover After the Battery Cover Screw has been removed the Battery Cover may be lifted to gain access to the battery Install battery pa...

Page 18: ...or cut insulation Check also for deterioration of the insulation Make certain that no wire is exposed and that the jack insulators and alligator boots are not cracked broken torn or otherwise damaged...

Page 19: ...battery annunciator _ is displayed This may cause the meter to produce inaccurate readings and lead the user to believe that no hazard exists when in fact dangerous voltages or currents are present WA...

Page 20: ...re high voltage WARNING IF IT IS NOT POSSIBLE TO TURN POWER OFF TO THE EQUIPMENT THEN THE USE OF A LINEMAN S GLOVE CONFORMING TO ASTM D120 IS REQUIRED For maximum safety turn the equipment or voltage...

Page 21: ...m the equipment Only after the leads are disconnected from the equipment should the range be changed After the new range is selected reconnect the leads as described above 8 3 High Current Measurement...

Page 22: ...by the presence of the annunciator When Auto is dis played the meter will select its own measurement range To select ranges manu ally press and release the RANGE button noting that the Auto annunciato...

Page 23: ...to be measured In this case press the RANGE button to select a higher range and attempt to measure the voltage again If you are already set to the highest range the voltage exceeds the measurement cap...

Page 24: ...y offset error The displayed reading should change to 000 X where X can be any number and the REL annuncia tor should appear in the display Do this before clamping the Jaws around the conductor Note D...

Page 25: ...accurate reading may be obtained by selecting a lower range Use the RANGE button to select the next lower range you ll need to press the button repeatedly to get to the next lower range Observe the r...

Page 26: ...position the meter will default to the Auto Resistance mode Make certain that the annunciator on the display is not visible If it is visible press the D HOLD button to turn it off Attach the test lead...

Page 27: ...the RANGE button to select the next lower range you ll need to press the button repeatedly to get to the next lower range Observe the reading on the LCD display If the RANGE is already on the lowest...

Page 28: ...Overrange OL indication Short the leads together The display should indicate about 000 0 Volts Referring to Figure 7 connect the test probes to the diode or circuit to be tested Observe the proper pol...

Page 29: ...ice or circuit being measured 9 6 Capacitance Test WARNING Do not apply voltage or current to the meter when it is set to Refer to Section 7 0 Preparation For Use and Section 8 0 General Measurement P...

Page 30: ...General Measurement Procedures before attempting any measurements Attach the test leads to the meter The red lead is connected to the V Hz Jack and the black lead is connected to the COM Jack Rotate t...

Page 31: ...rovided temperature probe into the COM and V Hz jacks observing proper polarity Apply the tip of the probe to the surface whose temperature is to be measured Read the temperature on the display Notes...

Page 32: ...ansers or chemical solvents that may dam age the case of the meter TRIPLETT PRODUCT RETURN INSTRUCTIONS In the unlikely event that you must return your Triplett equipment for repair the following step...

Page 33: ...56 Carrying Case Triplett PN 10 4289 Bead Type Temperature Probe Triplett PN 79 761 Thermocouple Adaptor Triplett PN 79 799 11 2 Model 101 G Line Separator Triplett PN 3264 Allows easy measurement of...

Page 34: ...visions of this warranty contact Triplett Corporation s Customer Service Department for a Return Authorization Number RMA and return instructions No returned product will be accepted without an RMA nu...

Page 35: ...35 Triplett Model 9310 A NOTES...

Page 36: ...36 Triplett Model 9310 A NOTES Test Equipment Depot 800 517 8431 99 Washington Street Melrose MA 02176 TestEquipmentDepot com...

Reviews: