background image

 
 

Introduction 

 

Congratulations on your purchase of the Triplett IRTUV50 
IR Thermometer with Built

in UV Refrigerant Leak Detector and Flashlight 

This thermometer makes non

contact (infrared) temperature measurements 

at the touch of a button. The built

in coaxial laser pointer increases target 

accuracy while the backlit LCD and handy multi

switch combine for 

convenient, ergonomic operation. The UV light source is convenient for 
locating leaks such as refrigerants 
 

Features 

 

 

 

 

Measures non

contact surface temperature up to 932°F ( 500°C ) 

 

12:1 Distance to Spot Ratio (Field of View) 

 

Precise non-contact measurements 

 

Multipoint laser sighting 

 

White LED built-in illuminators 

 

Blue LED built-in illuminators for UV function 

 

Unique flat surface, modern housing design 

 

Automatic Data Hold 

 

“MAX/MIN/AVG/DIFF” function 

 

Emissivity Digitally adjustable from 0.10 to 1.0 

 

Adjustable High and Low Alarms 
 
 

Safety  

 

 

  

International Safety Symbols 

  

This symbol, adjacent to another 
symbol or 
terminal, indicates the user must 
refer to the 

 

manual for further information 

 

Warnings 

 

Do not directly or indirectly point the laser at the eyes

 

 

of a person or an animal 

Summary of Contents for 614395004392

Page 1: ...User Manual IRTUV50 IR Thermometer with Built in UV Refrigerant Leak Detector and Flashlight...

Page 2: ...eatures Measures non contact surface temperature up to 932 F 500 C 12 1 Distance to Spot Ratio Field of View Precise non contact measurements Multipoint laser sighting White LED built in illuminators...

Page 3: ...only as described in this User Guide Cautions To avoid thermometer damage please avoid the following hazards EMF from welding equipment or electro induction heaters o Static electricity Thermal shock...

Page 4: ...Scan Icon 2 DATA HOLD 3 Laser ON Indicator 4 UV LED ON Indicator 5 HI and Low Alarm 6 Measurement Data 7 Work Light LED ON 8 C F Icon 9 MAX MIN AVG DIF Mode Indicator 10 Emissivity 11 APO Auto Power...

Page 5: ...ated below the display The available parameters are listed below Setting Mode Overview The Settings switch has five positions to select a parameter turn a parameter ON or OFF and to adjust parameter v...

Page 6: ...ter the Setting mode Advance until the UV icon flashes Press up for ON or OFF Press to store the setting 3 Temperature Units Setting Enter the Setting mode Advance until the F or C icon flashes Press...

Page 7: ...e until the Alarm LO icon flashes Press up or down for ON or OFF Press to store the setting If ON was selected Press up or down to adjust the limit Press to store the setting 9 Backlight Setting Enter...

Page 8: ...ll light if the batteries are good Replace the batteries if the display does not light 5 Release the Trigger the reading will HOLD for the time set in the APO setting The backlight will turn off after...

Page 9: ...displayed The values will be continuously updated for the length of the scan UV Leak Detector Inject a small amount of florescent dye into the system under test The dye system mixture refrigerant for...

Page 10: ...be so large that it encompasses surface areas not intended to be measured Emissivity Emissivity represents the energy reflectivity of a material Most organic materials and painted or oxidized surfaces...

Page 11: ...reading Repeatability of reading 8 of reading or 1 0 C 1 8 F whichever is greater Emissivity Adjustable from 0 10 to 1 00 Temp Coefficient 0 1 C C or 0 1 C of reading whichever is greater Field of Vie...

Page 12: ...61010 1 Warranty Triplett Jewell Instruments extends the following warranty to the original purchaser of these goods for use Triplett warrants to the original purchaser for use that the products sold...

Reviews: