17
Triple Solar assembly instruction PVT heat pump panels UK January 2021
Mounting connecting hoses
The connecting hoses must not contain any sharp bends after fixing. R >=80mm. See Figure 7.4.a.
1.
Grease TS plug/spigot ribbed hose (or possibly plug/swivel) at plug (use silicone valve grease,
see also chapter 7.2).
2. Push the TS plug/spigot ribbed hose (or plug/swivel where applicable) into the openings.
3. Place retaining clips over the header of the panels and into the slot in the TS plug/spigot ribbed
hose. See in Figure 7.4-a, at D.
Connecting the PV panels electrically
The instruction for the electrical connection of the heat pump panels is identical to regular PV
panels.
Mount optimizers, if you use them, as far as possible at the bottom edge of your panel field so that
you can always access them easily for maintenance. If necessary, use extension cables to connect
the panels to the optimizers in higher rows. (see figure 7.5-a) Connection is correct when
measuring 1Volt safety signal per optimizer.
D
Figure 7.4-a Attach retaining clip at (D)