Comfort
STEAM
TM
I n s t a l l a t i o n , O p e r a t i o n , & M a i n t e n a n c e M a n u a l
9
www.trioniaq.com
10. Cleaning the tank continued
4.
Pull the plastic tube attached to the bottom of the unit out of the rigid drain pipe on the wall. You do not have to remove the plastic
tube attached to the bottom of the pan. Remove the overflow pan from the unit by slightly loosening the front screw then lifting
the front of the pan off the screw and pulling it towards you. Please see Fig. 6. Remove the main drain tube from the rigid drain
pipe attached to the wall and check that they are both clean and clear from deposits.
5.
Check that the water tank is not too hot to handle. Unfasten the latch around the water tank and remove the tank from the main
body of the humidifier by pulling it down. When you remove the tank, it is possible to clean the round o-ring gasket, but don’t
discard it.
NOTE :This round gasket is mandatory and the unit will not work properly without it.
6.
Soap or vinegar can be used to clean the water tank, the heating element and the tips of the level sensors. Other cleaning
products used to remove scale, lime or calcium are also available on the market, but DO NOT use a metal brush or any strong
acids to clean the tank as they may damage the stainless steel.
4.
Once completed, reinstall the round gasket around the water tank collar. Please see Fig. 7. Align the two arrows located at the
front of the tank and the fixed part while lifting the tank in place. Please see Fig.8. Apply even pressure to secure the tank properly
in the top part. Then close the latch holding the tank in position. Verify that the o-ring gasket and tank are seated properly.
Figure 7
Figure 8
5.
Put the overflow pan under the tank by sitting it back on its holding screws.
6.
Reconnect the white wire of the overflow sensor on the water pan.
7.
Put the overflow and main drain tubes back into the rigid drain pipe attached to the wall.
8.
Put the cover back on the humidifier and lock it with the two quarter-turn screws.
9.
when finished, turn the main power back
“ON”
and readjust the humidistat to it’s previous setpoint.
11. Preventative Maintenance
Preventive maintenance to be performed every two years.
In order to avoid problems due to accumulation of deposits, we suggest that you replace the centre metal tube, the silicone drain tube
and the low level sensor. We also suggest you replace the round o-ring gasket around the tank. All these components are available
in a tune-up kit.
To prepare for the Summer Season
•
Shut the main power OFF
•
Shut the water supply valve
•
Perform a complete maintenance as described in section 8
•
Dry the inside of the tank
HOMEOWNER