10. Cleaning the tank continued

4. 

Pull the plastic tube attached to the bottom of the unit out of the rigid drain pipe on the wall. You do not have to remove the plastic 

tube attached to the bottom of the pan. Remove the overflow pan from the unit by slightly loosening the front screw then lifting 

the front of the pan off the screw and pulling it towards you. Please see Fig. 6. Remove the main drain tube from the rigid drain 

pipe attached to the wall and check that they are both clean and clear from deposits.

5. 

Check that the water tank is not too hot to handle. Unfasten the latch around the water tank and remove the tank from the main 

body of the humidifier by pulling it down. When you remove the tank, it is possible to clean the round o-ring gasket, but don’t 

discard it.  

       NOTE :This round gasket is mandatory and the unit will not work properly without it.

6. 

Soap or vinegar can be used to clean the water tank, the heating element and the tips of the level sensors. Other cleaning 

products used to remove scale, lime or calcium are also available on the market, but DO NOT use a metal brush or any strong 

acids to clean the tank as they may damage the stainless steel.

4. 

Once completed, reinstall the round gasket around the water tank collar. Please see Fig. 7. Align the two arrows located at the 

front of the tank and the fixed part while lifting the tank in place. Please see Fig.8. Apply even pressure to secure the tank properly 

in the top part. Then close the latch holding the tank in position. Verify that the o-ring gasket and tank are seated properly.

Figure 7

Figure 8

5. 

Put the overflow pan under the tank by sitting it back on its holding screws.

6. 

Reconnect the white wire of the overflow sensor on the water pan.

7. 

Put the overflow and main drain tubes back into the rigid drain pipe attached to the wall.

8. 

Put the cover back on the humidifier and lock it with the two quarter-turn screws.

9. 

when finished, turn the main power back 

“ON”

 and readjust the humidistat to it’s previous setpoint.

11. Preventative Maintenance

Preventive maintenance to be performed every two years.

In order to avoid problems due to accumulation of deposits, we suggest that you replace the centre metal tube, the silicone drain tube 

and the low level sensor. We also suggest you replace the round o-ring gasket around the tank. All these components are available 

in a tune-up kit.

To prepare for the Summer Season

• 

Shut the main power OFF 

• 

Shut the water supply valve 

• 

Perform a complete maintenance as described in section 8 

• 

Dry the inside of the tank

HOMEOWNER

Summary of Contents for ComfortSTEAM

Page 1: ...w w t r i o n i a q c o m ComfortSTEAM TM Humidification System READ AND SAVE THESE INSTRUCTIONS Notice to Contractor Once installation is complete please leave this manual with the customer for futur...

Page 2: ...Functions of the Electronic Circuit 6 8 What to do if a Malfunction Occurs 7 9 Description of Error Codes 7 10 Cleaning the Tank 8 11 Preventative Maintenance 9 CONTRACTOR INSTRUCTIONS SECTION 12 Unp...

Page 3: ...er unit or component requires service it must be performed by a competent heating and or air conditioning contractor preferably the installing contractor Trion will not pay shipping charges or labor c...

Page 4: ...tallation 6 Do not install a humidifier if the city water pressure exceeds 90 psi Check the local codes related to pressure reduction 7 Do not install the steam delivery stub or steam diffuser in the...

Page 5: ...possible the humidifier also drains after a certain number of boiling refill cycles This is determined by the DIP switches on the lower right corner of the electronic control board If there is still...

Page 6: ...on will reset the error code The COMFORTSTEAM humidistat also has two pilot lights to indicate the current status The green light is lit when the humidistat is demanding for humidity thus activating t...

Page 7: ...OFF then Open the unit and check for leaks Check the drain tube Close the supply valve and call for service Automatic Reset when switching main power ON again 1 Problem with the water level sensors i...

Page 8: ...ity You may have to adjust the setpoint higher to make this happen then cycle the main power and the unit will enter a drain cycle It may take a few minutes for the tank to begin filling as it needs t...

Page 9: ...clean the tank as they may damage the stainless steel 4 Once completed reinstall the round gasket around the water tank collar Please see Fig 7 Align the two arrows located at the front of the tank a...

Page 10: ...ending on the humidifier model 1 Instruction and maintenance manual 1 Plastic bag containing installation material and hardware as follows 2 Adjustable hose clips for the steam hose 1 Water hammer abs...

Page 11: ...STEAMTM I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 11 www trioniaq com 13 Dimensions and available models Figure 10 Humidifer Dimensions Figure 11 Available Models CON...

Page 12: ...ComfortSTEAMTM I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 12 www trioniaq com 14 Detailed View of Wiring Figure 12 Top of Unit CONTRACTOR...

Page 13: ...ComfortSTEAMTM I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 13 www trioniaq com View and list of the wire harness by color and function CONTRACTOR...

Page 14: ...m air duct for the steam diffuser For a horizontal duct make the 1 1 8 hole in the lower third of the duct height Please see Fig 13a For a vertical duct make the 1 1 8 hole in the middle of the duct P...

Page 15: ...andatory to allow any condensation to flow back naturally to the water tank Please see Fig 14e If condensation water accumulates in the hose the steam will not be able to escape normally through the s...

Page 16: ...is the overflow sensor Remove the water pan by lifting the front off its holding screw and pull towards you Do not remove those screws from the humidifier middle wall The humidifier must be installed...

Page 17: ...nimum free vertical length of 18 It is very important to leave an air gap between the rigid pipe and the tubes to allow the siphon to function properly The flexible tubes cannot touch the water contai...

Page 18: ...ber mentioned below is not included Route water supply line as required The water intake fitting on the top of the humidifier must be wrapped with teflon tape Screw the water hammer absorber piece of...

Page 19: ...pressure probe to the humidifier Warning Before installing anything on a duct always check that you are not about to cut or drill into an air conditioning coil or electrical accessories Drill a hole 3...

Page 20: ...hese contacts is 3A 240VAC or 6A 120VAC Please do not exceed these ratings Adjusting the DIP switches located on the lower right corner of the circuit board will change how the humidifier handles auto...

Page 21: ...to power the humidifier The green light will come ON confirming that the unit is ready to work Turn the humidistat clockwise past the middle of the scale to create a demand for humidity The tank fill...

Page 22: ...ComfortSTEAMTM I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 22 www trioniaq com CONTRACTOR 22 Wiring diagrams...

Page 23: ...ComfortSTEAMTM I n s t a l l a t i o n O p e r a t i o n M a i n t e n a n c e M a n u a l 23 www trioniaq com CONTRACTOR...

Page 24: ...Trion 101 McNeill Rd Sanford NC 27330 P 800 884 0002 F 800 458 2379 www trioniaq com customerservice trioniaq com Trion 2015 All Rights Reserved Form No 167649 001 Rev 02 15...

Reviews: