THE TSM SERIES WEIGHING PLATFORM

 

The TSM Series Floor Scale weighing platform is a 
fully electronic, low profile platform, engineered to 
provide years of reliable service. It is available in 
wide range of sizes from 24” x 24” to 96” x 120”, and 
capacities from 1,000 lbs to 20,000 lbs.  

 

All platforms are equipped with four, corner mounted 
NTEP approved loadcells that are recessed into the 
scale frame for protection. Also included is a signal-
trim summing board enclosed in a watertight 
junction box. The junction box is accessible from the 
top of the scale for ease of service. 
 
The platform utilizes precision “ball and cup” style 
adjustable leveling feet designed to compensate for 
irregularities in the floor.  
 

OPTIONS 

  Foot Retaining Plates 

  Access Ramps 

  Side Protection Guards  

  Indicator Mounting Stand 

  Pit Frame for In-ground Installations 

  

UNPACKING THE PLATFORM  

All Triner Low Profile Floor Scale weighing 
platforms are shipped LTL on a pallet. Remove 
the packing material and inspect the scale for 
any damage that may have been caused during 
shipment.  
 

THE DIGITAL INDICATOR, LEVELING FEET AND 
ANY SMALL ACCESSORIES ORDERED ARE 
SHIPPED SEPARATELY VIA UPS GROUND. 

Summary of Contents for TSM Series

Page 1: ...w trinerscale com SUG Version 2 0_02 15 13 Guide for setting up the Triner TSM Low Profile Floor Scale Platform and connecting to any of the following digital indicators TS 700 SS 7600e DIGITAL INDICA...

Page 2: ...without notice For Parts Service and Support Look for a Service Sticker on ALL sides of the Digital Indicator If a service sticker is present contact the servicing dealer The servicing dealer is usua...

Page 3: ...Installing and Leveling the Platform 4 Connecting the Digital Indicator to the Weighing Platform 6 Standard TSM Series Indicators 6 Connecting a TS 700 MS Indicator 6 Connecting a TS 700 SS Indicator...

Page 4: ...nclosed in a watertight junction box The junction box is accessible from the top of the scale for ease of service The platform utilizes precision ball and cup style adjustable leveling feet designed t...

Page 5: ...ration of the scale digital indicator please see the User s Guide that is included with the digital indicator BE SURE TO UNPACK ALL ITEMS IN THE DIGITAL INDICATOR SHIPPING CARTON The scale comes facto...

Page 6: ...ERFACE CABLE DAMAGE BE SURE TO PROTECT THE CABLE AND KEEP IT OUT OF HARM S WAY For best results the scale should be installed on smooth level concrete Installing the scale on dirt gravel or asphalt is...

Page 7: ...ct with the floor check the platform with a level to make sure it is within inch of level 5 MAKE CERTAIN that the platform does not rock from corner to corner Any amount of rocking will result in inac...

Page 8: ...NECTING CABLE WILL BE FOUND IN ONE OF TWO LOCATIONS DEPENDING ON THE MODEL OF INDICATOR PURCHASED IT WILL BE IN THE SHIPPING CARTON WITH THE INDICATOR OR BUNDLED INSIDE THE JUNCTION BOX AREA INSIDE TH...

Page 9: ...is ready for use CONNECTING A TS 700 SS INDICATOR OR CONNECTING A 7600E INDICATOR The interface cable is pre wired to the digital indicator and requires connecting the five wire leads into the weighin...

Page 10: ...E BARE END OF THE WIRE IS NOT PROPERLY SECURED THE SCALE WILL NOT OPERATE CORRECTLY THIS WILL BE THE MOST LIKELY CAUSE OF ANY PROBLEM YOU MAY HAVE WHEN USING THE SCALE FOR THE FIRST TIME 4 Once all th...

Page 11: ...dicator on After the power up sequence the display should indicate Zero If it does not press the ZERO key 10 When the digital indicator displays 0 the scale is ready for use Fig 3 0 JBox Wiring Diagra...

Page 12: ...perly repair cable Interface Cable wiring problem Check connections inside junction box and at indicator Display stays at Zero Scale will not weigh anything Item may be too light for scale resolution...

Page 13: ...evel the scale by properly adjusting the leveling feet Load cell connections faulty Check load cell connections inside junction box Load cell or load cell cable damage Inspect load cell cables Test an...

Page 14: ...Zero the indicator according to the indicator manual Platform binding Provide adequate clearance for free platform movement Make sure a ramp s is not touching the scale Remove any debris under and aro...

Page 15: ...platform 3 Make sure the scale is level Adjust the leveling feet if required to make sure all four feet are in contact with the floor 4 Periodic Calibration Notes a The scale is shipped factory calibr...

Page 16: ...oor Scale 14 g Calibrating the scale with anything other than industry standard test weights is not recommended or reliable Refer to your own quality standards to determine what kind of test weight is...

Page 17: ...ly with signal trim summing card JBOX 1 2 20 precision ball and cup leveling foot FOOT07 2 5k 2 500 lb Sheerbeam load cell LC002 5k 5 000 lb Sheerbeam load cell LC004 Load cell Bolt M12 x 1 75 x 50mm...

Page 18: ...responsible for warranty service should the Triner Scale label or logo or the serial number be removed or the product fail to be properly maintained or fail to function properly as a result of misuse...