Set Up Guide | Floor Scale
10
APPENDIX A: TROUBLESHOOTING AND
PERIODIC MAINTAINANCE
A.1 Troubleshooting Guide
Condition
Possible Problem & Correction
The system does not
operate – No Display.
•
Power disconnected or bad power
supply: Check outlet first. Test the
AC adapter or power supply.
•
Indicator fuse blown: Replace
fuse, check for cause.
•
Interface Cable cut or
disconnected: Replace or Properly
repair cable.
•
Interface Cable wiring problem:
Check connections inside junction
box and at indicator
.
Display stays at Zero.
Scale will not weigh
anything.
•
Item may be too light for scale
resolution.
•
Interface Cable cut or
disconnected: Replace or Properly
repair cable.
•
Interface Cable wiring problem:
Check connections inside junction
box and at indicator.
•
Load cell connections faulty:
Check load cell connections inside
junction box.
•
Debris under the scale platform:
Check and clean debris from
under the platform (Periodic
Maintenance).
•
Indicator faulty. Service or replace
indicator.