Number Axis Parameter Description
Range [Unit]
Acc.
183
smartEnergy
slow run current
Sets the motor current which is used below
the threshold speed.
0… 255
RW
184
Random chopper
off time
Enable randomizing the slow decay phase
duration:
0: Chopper off time is fixed (see axis
parameter 167).
1: Random mode. Chopper off time is
modulated by dNCLK= -12 … +3 clocks.
0/1
RWE
193
Reference search
mode
1 search left stop switch only
2 search right stop switch, then search
left stop switch
3 search right stop switch, then search
left stop switch from both sides
4 search left stop switch from both sides
5 search home switch in negative
direction, reverse the direction when
left stop switch reached
6 search home switch in positive
direction, reverse the direction when
right stop switch reached
7 search home switch in negative
direction, ignore end switches
8 search home switch in positive
direction, ignore end switches
Additional functions:
-
Add 128 to a mode value for inverting the
home switch polarity (can be used with
mode 5… 8).
-
Add 64 to a mode for exchanging left and
right stop switches (can be used with
mode 1… 4).
1… 8
RWE
194
Reference search
speed
For the reference search this value directly
specifies the search speed.
0… 2047
RWE
195
Reference switch
speed
Similar to parameter no. 194, the speed for
the switching point calibration can be
selected.
0… 2047
RWE
196
Reference switch
distance
This parameter provides the distance between
the end switches after executing the RFS
command (mode 2 or 3).
0… 2.147.483.647
R
197
Last reference
position
Reference search: the last position before
setting the counter to zero can be read out.
-2
31
… 2
31
-1
[µsteps]
R
200
Boost current
Current used for acceleration and deceleration
phases.
If set to 0 the same current as set by axis
parameter 6 will be used.
0… 255
RWE
204
Freewheeling
delay
Time after which the power to the motor will
be cut when its velocity has reached zero.
0… 65535
0 = never
[msec]
RWE
206
Actual load value Readout of the actual load value used for stall
detection (stallGuard2).
0… 1023
R