![Trinamic TMCM-351 Firmware Manual Download Page 7](http://html1.mh-extra.com/html/trinamic/tmcm-351/tmcm-351_firmware-manual_1163054007.webp)
TMCM-351 TMCL Firmware V4.45 Manual (Rev. 1.06 / 2014-MAY-16)
7
www.trinamic.com
4.
Connect the power supply:
Attention: Do not exceed the maximum power supply of 28.5 V DC!
Please connect the power supply as follows:
1
2
Pin
Label
Description
1
GND Module ground (power supply and signal ground)
2
VDD Power supply input, nom. +24V DC (+7 .. +28.5V DC)
5.
Switch on the power supply
The green LED for power should glow now. This indicates that the on-board +5V supply is available.
If this does not occur, switch power OFF and check your connections as well as the power
supply.
6.
Start the TMCL-IDE software development environment
The TMCL-IDE is on hand on the TechLibCD and on
Installing the TMCL-IDE:
-
Make sure the COM port you intend to use is not blocked by another program.
-
Open TMCL-IDE by clicking
TMCL.exe
.
-
Choose
Setup
and
Options
and thereafter the
Connection tab
.
-
Choose
COM port
and
type
with the parameters shown below (baud rate 9600). Click
OK
.