TMCM-1311 TMCL Firmware V1.11 Manual (Rev. 1.17 / 2015-NOV-05)
7
www.trinamic.com
1.
Choose your interface
According to default settings of the module, USB interface and CAN interface can be used without
any further configuration. For operation with RS485 interface, change interface setting (SGP 88
) first.
a)
CAN interface
Pin
Label
Direction
Description
1
2
CAN_L
Bi-directional
Differential CAN bus signal (inverting)
3
GND
Power (GND)
Signal and system ground
4
5
6
7
CAN_H Bi-directional
Differential CAN bus signal (non-inverting)
8
9
b)
RS485 interface
Before connecting the interface it is necessary to configure it. Therefore, use the USB or the CAN
interface and the software development environment TMCL-IDE. With global parameter 88 (
interface
selection
) the RS485 interface can be selected.
TMCL-command for changing to the RS485 interface:
SGP 88, 0
Pin
Label
Direction
Description
1
2
RS485- Bi-directional
Differential RS485 bus signal (inverting)
3
GND
Power (GND)
Signal and system ground
4
5
6
7
RS485+ Bi-directional
Differential RS485 bus signal (non-inverting)
8
9
c)
USB interface
For using USB interface download and install the file
TMCM-1311.inf
Pin
Label
Direction
Description
1
VBUS
Power
(+5V input)
+5V supply from Host
2
D-
Bi-directional
USB Data -
3
D+
Bi-directional
USB Data +
4
ID
Connected to signal and system ground
5
GND
Power (GND)
Signal and System ground
2.
Connect the motor
Pin
Label
Direction
Description
1
A1
Output
Pin 1 of motor coil A
2
A2
Output
Pin 2 of motor coil A
3
B1
Output
Pin 1 of motor coil B
4
B2
Output
Pin 2 of motor coil B