TMCM-1311 TMCL Firmware V1.11 Manual (Rev. 1.17 / 2015-NOV-05)
26
www.trinamic.com
5.7.3
MST (motor stop)
The motor will be instructed to stop.
Internal function:
the axis parameter
target velocity
is set to zero.
Related commands:
ROL, ROR, SAP, GAP
Mnemonic:
MST 0
Binary representation:
INSTRUCTION NO.
TYPE
MOT/BANK
VALUE
3
don’t care
<motor>
0
*
don’t care
* Motor number is always O as the module support just one axis
Reply in direct mode:
STATUS
VALUE
100 – OK
don’t care
Example:
Stop motor 0
Mnemonic:
MST 0
Binary:
Byte Index
0
1
2
3
4
5
6
7
Function
Target-
address
Instruction
Number
Type
Motor/
Bank
Operand
Byte3
Operand
Byte2
Operand
Byte1
Operand
Byte0
Value (hex)
$01
$03
$00
$00
$00
$00
$00
$00