TMCM-1260 Hardware Manual • Hardware Version V1.10 | Document Revision V1.20 • 2018-05-17
24 / 30
Operational Ratings of the I/Os
Symbol
Parameter
Min
Typ
Max
Unit
Table 12: Operational ratings of I/Os
Operational Ratings of the RS485 Interface
Symbol Parameter
Min Typ
Max
Unit
N
RS485
Number of nodes connected to single RS485 network
256
f
RS485
Max. speed for RS485 network
1Mbit/s
Table 13: Operational ratings of the RS485 interface
Operational Ratings of the CAN Interface
Symbol Parameter
Min Typ
Max
Unit
N
CAN
Number of nodes connected to single CAN network
>110
f
CAN
Max. speed for CAN network
1Mbit/s
Table 14: Operational ratings of the CAN interface
©2018 TRINAMIC Motion Control GmbH & Co. KG, Hamburg, Germany
Terms of delivery and rights to technical change reserved.
Download newest version at
www.trinamic.com