TMCM-1160 CANopen® Firmware Manual • Firmware Version V3.20 | Document Revision V2.10 • 2019-JAN-04
93 / 110
5
Index pulse
Home switch
5
Figure 13: Homing Method 5
9.1.5
Homing Method 17: Homing on negative Limit Switch
Using this method, the initial direction of movement shall be leftward if the negative limit switch is inactive
(here: low). The home position shall at the point where the negative limit switch becomes inactive.
17
Negative limit switch
17
Figure 14: Homing Method 17
9.1.6
Homing Method 18: Homing on positive Limit Switch
Using this method, the initial direction of movement shall be rightward if the positive limit switch is inactive
(here: low). The home position shall be at point the where the positive limit switch becomes inactive.
18
18
Positive limit switch
Figure 15: Homing Method 18